UWB transmit power: what the limits actually say
Rules change often. Check before you rely on this. This article is an engineer's summary, not legal advice. Last reviewed November 2026. Confirm the current rules for your product and markets before you commit to a design or a test plan.
UWB range starts with a number set by a regulator, not by an engineer. It is worth knowing what that number is, how it is measured, and where the edges are, because every decibel a product sits below the limit is range it gave away.
Two limits, both on what is radiated
In the US, UWB devices fall under FCC Part 15, Subpart F. For the 3.1 to 10.6 GHz band there are two limits, and a product has to meet both:
- Average: -41.3 dBm in any 1 MHz, measured with an RMS detector and an averaging time of one millisecond or less.
- Peak: 0 dBm in a 50 MHz bandwidth, centered on the frequency where the emission is strongest.
Both are EIRP: the power radiated in the strongest direction, antenna included. What comes out of the chip is only the starting point. Loss on the way to the antenna can be made up. Antenna gain has to be given back: an antenna with 3 dB of gain in its best direction means 3 dB less from the chip.
Spread across a 500 MHz channel, the average limit comes to about -14 dBm in total, or about 37 microwatts.
Which kind of device you are
The US rules sort UWB communication devices into classes, and the class sets more than the paperwork.
- Indoor devices (47 CFR 15.517) must be usable only indoors, for example because they depend on mains power, and may not use outdoor antennas.
- Handheld devices (47 CFR 15.519) may be used outdoors, but may not use fixed outdoor infrastructure, and must stop transmitting within ten seconds if they stop hearing an acknowledgment from the device they are talking to. A tag that only transmits, with nothing answering it, needs a careful read of that rule.
The limit inside the band is the same for both. Outside it, the handheld limits are about 10 dB tighter in several bands. A system with mains-powered anchors and battery tags can have both classes in it, and a fixed anchor on an outdoor pole does not fit either one. If that is your product, raise it with the lab on day one.
This may change. In November 2026 the FCC proposed to update the UWB rules, including a new category for compact devices that may be fixed or mobile, indoors or outdoors, and it asked whether the emission limits should be revisited. It is a proposal, and the rules above apply until a final rule is adopted. The FCC proposes to update the UWB rules covers what is in it.
What the averaging time means for short frames
The average is taken over a millisecond. A frame shorter than that, sent no more than once per millisecond, can carry more power while it lasts and still meet the average. Halve the frame and the allowance is 3 dB. Some older chips have this built in, and step the power up for frames under about half, a quarter, and an eighth of a millisecond. They raise only part of the frame: the header stays at the normal level.
Three cautions. The peak limit still applies, and it has to be checked at the higher power. The allowance disappears if two frames can land in the same millisecond. And the frames that are short enough carry very little data, so this suits a tag that blinks, not one that talks.
Measuring it
A pre-scan is only useful if it measures what the lab will measure, the way the lab will measure it.
- Measure radiated, in the strongest direction. A conducted measurement at the antenna connector plus an assumed antenna gain is a guess.
- Average and peak need different setups. The average is an RMS measurement in 1 MHz. The peak is a peak-detector measurement defined in 50 MHz. Using the wrong detector for either gives a number that means nothing. The rules give a formula for using a narrower bandwidth (at 3 MHz the limit becomes about -24 dBm), but at least one chip vendor warns that results taken that way do not match a true 50 MHz measurement. Ask the lab how they will measure peak, and measure the same way.
- Look outside the band. The limits there are far lower, and lowest of all in the GPS bands, where they are also measured in a much narrower bandwidth. Harmonics, clock leakage, and anything an amplifier adds show up here.
Why products end up turned down
- Unit-to-unit spread. Chips vary by a couple of decibels. Without per-unit calibration, every unit has to be set low enough that the hottest one passes.
- Temperature and voltage. On older chips the output can move several decibels across the operating range. Newer parts that publish the figure are much flatter. Either way, know the number for yours.
- Antenna gain. A peak in the pattern at one angle and one frequency sets the level for the whole product.
- Something outside the band. One spur fails the test, and the quickest fix on test day is to turn everything down.
- The spectrum shape. A pulse that does not fill the channel evenly reaches the limit at its highest point while the rest sits below it.
Calibrating transmit power on every unit in production, in the enclosure, is the most reliable way to stay close to the limit, and UWB production calibration covers the station that does it. Why UWB range falls short of the datasheet covers the rest of the link.
Europe, and elsewhere
The EU’s generic limits for the 6 to 8.5 GHz band are the same two numbers: -41.3 dBm/MHz average and 0 dBm peak in 50 MHz. That band needs no extra measures. The lower band, around 3.1 to 4.8 GHz, reaches the same level only with a mitigation technique such as a low duty cycle or detect-and-avoid, and is otherwise held far lower. That is one likely reason newer chips cover only the channels near 6.5 and 8 GHz.
Since 2024 the EU also has a category for enhanced indoor devices in the 6 to 8.5 GHz band, for uses such as location tracking: 10 dB more, average and peak, with transmission limited to 5 percent of each second, indoors only, and with carried devices allowed the higher level only under the control of the indoor infrastructure (Decision (EU) 2024/1467). It is new. Check the current harmonized standard and the conditions with your lab before relying on it. Fixed outdoor installations have their own section, with their own conditions.
Other markets set their own bands and conditions. Japan, Korea, and China each allow different parts of the spectrum, and a channel that is fine in the US and the EU is not automatically allowed elsewhere. List the markets first, then choose the channel. Compliance by market and the compliance planner are a place to start.
Before the layout
Three decisions set most of this, and all three are cheap on paper: the markets, the device class in each, and the channel. Then plan the per-unit calibration and the pre-scan, so the product goes to the lab sitting just under the limit and not well below it.
If you would like that plan checked before the board is laid out, get in touch.