IPC-2221 relates the current a trace can carry to its copper cross-section and the temperature rise you allow. A 1 A trace in 1 oz copper on an outer layer, allowed to rise 10 °C, needs about 0.30 mm (12 mil); on an inner layer, IPC-2221 asks for about 0.78 mm (31 mil).
Find the width for a current, the current a width can carry, or how hot a given trace runs, with its resistance, voltage drop and power loss, and how many vias the current needs. The formula is a starting point, not a guarantee: the notes below say where it falls short.
What the formula uses
IPC-2221 publishes charts of trace current against cross-section and temperature rise. The common curve fit to those charts gives the current I (amps) a trace carries for a rise ΔT (°C) above ambient, from its cross-section A, width times copper thickness, in square mils:
I = k × ΔT0.44 × A0.725
k is 0.048 for outer layers and 0.024 for inner layers. For a via, A is the ring of plating in the barrel. The current grows more slowly than the cross-section, so a trace twice as wide carries only about 1.65 times the current.
Result
Minimum width
–
Voltage drop
–
| Same current | Width |
|---|
Vias
A worked example
A 1 A trace in 1 oz copper (35 µm, 1.378 mil) on an outer layer, allowed to rise 10 °C: the formula gives a cross-section of (1 / (0.048 × 100.44))1/0.725 = 16.3 square mils, and dividing by the thickness gives 11.8 mil, or 0.30 mm. On an inner layer the same current needs 0.78 mm, 2.6 times as wide. Allowing a 20 °C rise instead narrows the outer trace by only about a third, to 0.20 mm. Over 50 mm, with a 25 °C ambient so running at 35 °C, the 0.30 mm trace has about 87 mΩ of resistance, so it drops 87 mV and turns 87 mW into heat. On a 3.3 V rail that is 2.6% of the supply.
How far to trust the result
The IPC-2221 curves come from measurements made in the 1950s. Its inner-layer value is not a separate measurement: it is the outer-layer curve with the current halved, as a cautious allowance. IPC-2152, published in 2009 after new testing, found that inner traces often run cooler than outer ones. The board around a trace matters as much as the trace: board thickness, copper planes nearby, and the amount of copper around it all change the temperature rise a lot, and the formula sees none of them. It can also understate the rise: on thin boards, boards without planes, closely spaced power traces, or in a sealed enclosure, a trace can run hotter than the formula says.
So treat the width here as a starting point, not a guarantee. Where you have room, go wider. For a trace that carries real power, measure it on the first boards: run full current and check the temperature with a thermocouple or a thermal camera.
The formula’s range
The IPC-2221 curves are commonly quoted as covering currents up to 35 A on outer layers (17.5 A on inner), widths up to 400 mil (10.2 mm), temperature rises of 10 to 100 °C, and copper from 0.5 to 3 oz. Outside that range the calculator still answers, but it flags the result: it is an extrapolation of the curves, not something they were drawn from. It also notes when the trace would run above 105 °C: the board material and nearby parts set a limit too.
Voltage drop is often the real limit
For long runs, low-voltage rails and high currents, the voltage drop can matter well before the trace gets warm. The resistance here uses the resistivity of annealed copper, 1.724 µΩ·cm at 20 °C, rising 0.393% per °C, at the trace’s running temperature. Board copper can measure a little higher. It is the DC resistance: at high frequencies the current crowds toward the copper surface and the resistance rises. Doubling the width, or the copper weight at the same width, halves the resistance. The length is one way: where the return current flows in a trace rather than a plane, double it for the loop.
Vias
IPC-2221 was not written for vias. Applying its formula to the plated barrel’s cross-section is common practice, usually with the outer-layer constant; the calculator also gives the more cautious inner-layer figure. A via’s barrel is short and joins copper at both ends, which draws heat away, so it can run cooler than a trace of the same cross-section. The plating thickness varies from board to board and down the hole, so ask the board house for its value. Use more vias than the minimum where there is room: they cost little, and current does not always share evenly between them. Spread them out, too: vias packed tightly heat each other.
Common questions
How wide should a PCB trace be for 1 A?
By IPC-2221, about 0.30 mm (12 mil) in 1 oz copper on an outer layer for a 10 °C rise, and about 0.78 mm (31 mil) on an inner layer. Allowing a 20 °C rise brings the outer trace down to about 0.20 mm (8 mil). Wider is cheap where there is room, and it also lowers the voltage drop.
Why does IPC-2221 make inner-layer traces so much wider?
Its inner-layer rule is the outer-layer curve with the current halved, a cautious allowance rather than a separate measurement. Because current grows more slowly than cross-section, halving the current for the same rise means about 2.6 times the width. Later testing for IPC-2152 found that inner traces often run cooler than outer ones, so the IPC-2221 inner value usually errs on the safe side.
How much current can a via carry?
A through via with a 0.3 mm finished hole and 20 µm of plating, the calculator’s starting values, has about 0.020 mm² of copper in its barrel, and the IPC-2221 outer-layer formula gives it about 1.6 A for a 10 °C rise. Use several vias for anything that matters: they cost little, and current does not always share evenly between them.
Want a second look at your layout?