What a BMS does, and why series cells need balancing
Cells in series carry the same current, but they don’t stay at the same charge: self-discharge, leakage and temperature differ from cell to cell, so they drift apart, and their capacities differ as well. A charger that only sees the pack voltage then lets the highest cell go past its limit while the pack still reads “not full”, and on discharge the lowest cell reaches empty first. A battery management system (BMS) measures every cell’s voltage, the pack’s current and its temperatures, stops charge and discharge on the worst cell, balances the cells back together, and reports state of charge and health. Passive balancing bleeds the high cells through resistors, typically tens of milliamps per cell through a monitor’s built-in switches and up to about 240 mA on a high-current monitor. That removes routine drift in minutes, while a one-off 10 percent imbalance takes hours to days.
This builds on How lithium-ion charging works, which defines the terms (charge voltage, C-rate, state of charge). Protection, its switches and fuses have their own article; this one is about what changes when there’s more than one cell.
Series, parallel and what the pack sees
4S2P means four groups in series, each of two cells in parallel. The pack voltage is the cell voltage times the number in series, and its capacity one cell’s times the number in parallel. Eight 3 Ah, 3.6 V cells as 4S2P make a 14.4 V, 6 Ah pack of 86.4 Wh; add a third cell to each group, 4S3P, and it’s 129.6 Wh, past the 100 Wh line that changes how a battery shipped on its own is classed for air transport.
Cells in parallel sit at the same voltage and share charge between themselves, so to the BMS a parallel group is one large cell. That also hides a bad cell, as below.
Joining cells in parallel
Cells joined at different voltages charge each other, limited only by their resistance. With an example 30 mΩ per cell (one 21700 sheet’s DC figure) and a 10 mΩ link, two cells 0.3 V apart push about 4.3 A through each other on connection, well above the 2.45 A standard charge on another maker’s 21700 sheet. Even 0.17 V is enough to reach that current with these values, and a single cell joined to a group of four sees about 6.3 A from the same 0.3 V; lower-resistance cells and welded links give more. Bring cells to the same voltage, as closely as you can measure, before they’re joined.
Matching, and the cell hidden in a group
Parallel cells with different resistances don’t share current evenly: the lower-resistance cell carries more and ages faster. One study cycled pairs of LiFePO4 cells in parallel at a high rate (4.5C charge and discharge) and found that a 20 percent difference in internal resistance cut cycle life by about 40 percent against a well-matched pair. That’s one chemistry at a punishing rate, so take the direction from it, not the number. New cells can be close: a study of 1,100 fresh LiFePO4 cells from one batch reported a variation of about 0.28 percent in capacity and 0.72 percent in impedance, as a statistical spread, so individual cells sit further apart than that. For a matching tolerance, ask your cell supplier, and match resistance as well as capacity.
A cell that fails open inside a group takes its capacity with it, and the group becomes the weak cell of the pack. A cell that shorts internally is worse: its parallel neighbours discharge into it, and the pack’s protection, in series with the whole string, can’t see current flowing within a group. Cell-level fusing, a fusible link on each cell’s connection, opens on that current and isolates the shorted cell. It needs enough cells in the group to drive the fault: in a two-cell group, the one healthy cell carries the same current as the shorted one, so both links see it, and a soft short may not open either. The link has to carry the normal current per cell and open on what the rest of the group can push into a short.
Why series cells drift apart
In a series string every cell carries the same current, so the charge in and out is identical. Their charge drifts only through what happens to one and not the others: self-discharge, leakage into whatever is connected across it, and differences in coulombic efficiency, the small share of each charge lost to side reactions, which rises with temperature. Differences in capacity and impedance don’t move charge between them, but they make the cells’ voltages and states of charge diverge. One gauge maker’s application note lists “cell-to-cell differences in self-discharge, capacity, and impedance”, and adds that a charger terminating on the summed voltage “may leave some cells undercharged and others overcharged”. A temperature gradient across the pack adds to it: warmer cells age faster, so their capacity falls away from the rest. And a weak cell, driven through a wider swing of its own capacity on every cycle, tends to decay faster than the others.
The BMS itself is one of the leaks. On one monitor family the current into each cell’s sense input is 8 to 12 µA per cell input with its converter on, and adjacent inputs may differ by up to 1.8 to 2 µA, depending on temperature range. Two microamps for a year of the converter running is 17.5 mAh: small, and in sleep or shutdown the figure doesn’t apply. A bigger leak is any load powered from part of the stack, such as a regulator or a monitor section fed from the bottom few cells, which drains those cells alone, all the time; feed loads from the whole stack. Differences in self-discharge between healthy cells add to it; ask the cell maker for the spread.
Imbalance in charge against a difference in capacity
Balancing fixes only one of two kinds of imbalance. A difference in charge is an offset: cells of the same capacity holding different amounts. Take four of those 3 Ah cells in series, with one holding 150 mAh more than the other three. Charging has to stop when that cell is full, leaving the other three 150 mAh short. On discharge the three run out first, with the high cell still holding 150 mAh. The pack delivers 2.85 Ah of its 3 Ah, and the 150 mAh is recoverable: bleed the high cell down at the top of charge, and the next charge fills all four.
A difference in capacity isn’t an offset. If one cell has 2.91 Ah and the rest 3 Ah, a perfectly balanced pack is a 2.91 Ah pack, and no amount of bleeding changes that. One power cell’s sheet gives 4.35 Ah minimum and 4.5 Ah typical, about 3 percent apart, so cells anywhere above that minimum meet the sheet, and the pack is limited by its smallest. A pack balanced at the top delivers its smallest cell’s capacity; an offset in charge takes more off that, and balancing recovers only the offset.
What the charger sees
On charge, the danger is the cell that reaches its limit first. A 4S pack charged to 16.8 V, four times 4.2 V, looks right at the pack terminals. If three cells sit at 4.18 V, the fourth is at 4.26 V, past the 4.25 V maximum of a cell specified at 4.20 ± 0.05 V, before counting the charger’s own tolerance, and the pack voltage can’t show it. So the charge has to stop, or the current has to drop, on the highest cell’s voltage, and the charge-voltage budget in the tolerances article applies to that cell, not to the pack divided by four.
On any multi-cell design, I’d want to see what stops the charge when the highest cell reaches its limit, not when the pack voltage does.
On discharge it’s the lowest cell, which reaches its cutoff while the others still have charge. Carry on past that, and the stronger cells can drive it through 0 V into reversal, which is the damage the protection article explains.
Balancing
Passive: bleeding the high cells
Passive balancing puts a resistor and a switch across each cell and turns the switch on for the cells that are ahead, turning their extra charge into heat. It’s cheap and simple, and limited by current and heat.
Monitors with built-in balance switches handle small currents: up to 50 mA per cell on one family, and only up to 5 mA on its larger members; external switches allow much higher currents. One monitor’s application note works the current for a 4.2 V cell through two 20 Ω input filter resistors and a 25 Ω internal switch: 4.2 V / 65 Ω, about 65 mA, with about 0.1 W in the switch inside the chip. The filter resistors take about 0.08 W each, so it’s about 0.27 W per balancing cell, and the chip’s share adds up when several cells bleed at once.
That current flows in the sense path, so balancing and measuring get in each other’s way. While the switch is on, the chip’s input pins for that cell see roughly the voltage across the 25 Ω switch, about 1.6 V, not 4.2 V, and each filter resistor drops about 1.3 V, which shifts the readings of the cells either side. So monitors pause balancing to measure: one family balances about 70 percent of each 250 ms cycle, and another pauses balancing on the cell being measured on every loop, which “can result in significant reduction in the average balancing current”. One datasheet also says adjacent cells shouldn’t be balanced at the same time.
Balance current against the imbalance
Hours to balance = imbalance in mAh / average bleed current in mA. Routine drift is small: 2 µA of uneven drain is about 1.4 mAh a month, which 35 mA removes in under three minutes. At 50 mA and a 70 percent duty, a 100 mAh offset takes about 2.9 hours. An older application note works a 10 percent difference on a 2,000 mAh pack: 134 hours of charge time at its internal bypass (6.8 mA at a 22 percent duty), or 14 hours with a 65 mA external bypass. Scale to an example 20 Ah pack, and the same 10 percent is 2 Ah: about 57 hours at 35 mA average, which already needs the smaller family’s internal switches or external ones; at the larger members’ 5 mA it’s weeks. A high-current monitor rated for 240 mA per cell, up to 8 cells at once at 75 °C ambient, would take over 8 hours even at full duty, and those 8 cells at 240 mA are about 8 W of heat inside the pack.
Size the bleed for two things: the steady drift, which must be less than the bleed removes each cycle or the pack walks apart however long it’s given, and the one-off offset, such as cells assembled at different charge or a cell replaced, which sets how many charges stop short before balancing catches up. A small pack of matched cells from one batch, with nothing drawing from part of the stack, may drift so little that a modest bleed is ample; it still needs the charge to stop on the highest cell. And a balance switch stuck on drains its cell steadily: 65 mA empties a 3 Ah cell in about 46 hours, so a balance fault should be detected and stop the pack.
Bleed resistors also warm whichever cells are nearest, creating the temperature gradient that causes drift, so place them where their heat reaches the cells evenly or not at all, and count the monitor’s thermal pause in the time budget.
When in the cycle to balance
Balance at the top of charge, where the differences matter. One monitor family lets you choose to balance while charging, while the pack is at rest, or both, and only above a set minimum difference between cells, which has to sit above the monitor’s own error or it balances on noise. At rest, readings carry no current-times-resistance error, so they compare charge. During charge, a bleed only slows the high cell: it keeps charging until the pack current falls below the bleed current. A 3 Ah cell’s 0.02C termination is 60 mA, so a bleed averaging 35 mA can’t hold a cell still even at the end of constant voltage, and in constant current it’s about 2 percent of a 0.5C charge. So balancing often continues after the charger stops, or the charger holds a reduced current near the top so the low cells catch up while the high ones are held back.
Balancing on voltage in the middle of a discharge can make the pack worse. Under load, the readings mostly show differences in resistance and temperature, and even at rest, cells of different capacity balanced at the top legitimately sit at different voltages mid-discharge, so balancing there undoes the top balance. LiFePO4’s flat curve makes voltage a poor guide anywhere in the middle. One gauge maker’s table marks the range where its gauge won’t use a voltage reading to recalibrate: for one LiFePO4 cell, 3,274 to 3,351 mV, covering 34 to 93 percent state of charge, about 1.3 mV per percent on average; for a standard lithium-ion cell it’s 26 to 54 percent, at about 2.3 mV per percent, its flattest stretch. A monitor accurate to ±15 mV in that voltage range, as the loosest family here is, can’t place a LiFePO4 cell on that plateau better than about ±11 percent on average, and much worse on its flattest parts. So LiFePO4 packs are balanced at the top of charge, on the steep rise above the plateau, which works only if charges regularly reach it: a pack held part-charged never gives a usable signal. Counting charge doesn’t help, since every cell in series sees the same current.
Active: moving charge instead of burning it
Active balancing moves charge from high cells to low ones through an inductor, a capacitor or a transformer, and can work during discharge as well as at the top. In principle that lets a pack use more than its smallest cell’s capacity, by feeding that cell from the others as it runs down. The costs are a converter per cell or group, its control, its own losses and failure modes, and more parts on the most crowded board in the pack. Active balancing can move far more current than a bleed resistor; check the transfer efficiency and the current against the drift and capacity spread it has to cover.
What else a BMS does
Measuring every cell, and knowing when it can’t
Per-cell decisions rest on the monitor’s accuracy. Three monitor families span about ±2 mV to ±10 mV at 25 °C (the last only from 3.6 to 4.3 V; ±15 mV from 3.2 to 4.6 V), widening to about ±3.5 mV, ±15 mV and ±40 mV over their full temperature ranges, the middle one only after a board offset calibration. At 4.2 V, ±40 mV is about 1 percent, twice the ±0.5 percent of a good single-cell charger, so in a multi-cell pack the monitor can be the loosest term in the charge-voltage budget. On a cell specified at 4.20 ± 0.05 V, a ±40 mV monitor has to stop the charge at a reading of 4.21 V at most, before any other error, to keep the cell under 4.25 V. A hardware overvoltage comparator has its own accuracy, separate from the measurement’s. The calibrated part’s figure needs that calibration in production test (designing for production test).
A broken sense wire matters most. With filter capacitors on the inputs, an open tap can float to a plausible voltage, and the monitor reads two cells as their sum split some way between them; split the wrong way, an overvoltage hides. To detect it, switch a small load or the balance path on a tap and check that the readings either side move as they should. Comparing the sum of the cells with the pack voltage won’t find it: an open middle tap cancels out of the sum, so that check catches only the top and bottom. Treat an open tap as a fault that stops charging. Sense wires are also unfused paths to the cells: a short between two of them, in a harness or on the board, is a short across cells, so many designs put a series resistor or fuse at the cell end. And read the monitor datasheet for the order its cell taps may be connected in during assembly, or what it survives in any order.
Per-cell secondary protection checks each cell in hardware: protectors for two to four cells compare each cell with a reference, and “If one cell reaches an overvoltage condition, the protection sequence begins”. A lithium titanate cell maker puts the requirement plainly: “In battery systems, the battery management system must enforce the voltage limits at the individual cell level”.
Temperature, switches and current
Large packs need more than one temperature sensor, because the charge limits apply to the hottest and the coldest cell, which are rarely next to each other.
Low-side charge and discharge switches are cheaper and easier to drive, but when they open the system’s ground moves away from the cells’ negative, and every wire between pack and system becomes a possible sneak path. High-side switches keep the ground common, which suits a BMS that talks to the host and charger over a wired bus, at the cost of a gate drive above the pack voltage. The protection article covers the rest.
The current sense resistor has to read everything from the short-circuit current down to the termination current and the standby drain, and its offset limits coulomb counting at low currents.
State of charge, health and talking to the charger
Pack state of charge is set by the cells at the extremes: the pack is full when its highest cell is full and empty when its lowest is empty, so a pack gauge that tracks only the total overstates what’s left once the cells drift. Health is tracked as capacity and resistance per cell or group, the resistance from each cell’s voltage step when the current changes; the one that climbs fastest is the weak cell. A rapid rise in resistance often accompanies the late-life “knee” where capacity starts to fall quickly, so watch for a cell whose resistance climbs faster than the rest.
Communication carries cell voltages, temperatures, current, state of charge and faults to the host, and can ask the charger to reduce current as the highest cell nears its limit, giving the bleed time to work instead of tripping the protection. That link mustn’t be the only protection. IEC 62133-2 says “Each battery should have an independent control and protection for current, voltage, temperature and any other parameter required for safety”, and allows that protection to sit in the charger or the end device, provided the battery maker passes the safety information on. In practice, the pack’s switches have to open on the per-cell limits with the link down and the host crashed.
Without a dedicated monitor, a BMS built from a processor, references and discrete switches has to provide everything above itself, including limits that hold if the firmware stops.
Pack-level hazards
Inrush and precharge
A pack connected to a large input capacitance sees a near-short until it charges. Take an example 14S pack at 58.8 V full and an example 1,000 µF on the bus: with an example 50 mΩ through the cells, switches and wiring, the first instant is limited only by that resistance and the wiring’s inductance, to hundreds of amps or more, far past any short-circuit threshold. A precharge circuit closes a resistor path first. Through an example 100 Ω resistor the peak is under 0.6 A, the time constant is 100 ms, and the capacitors are within 1 percent after about half a second. The resistor absorbs about 1.7 J, the same as the capacitors end up storing, whatever its value. Into a shorted bus, though, it sits across the full pack voltage, about 35 W here, so the BMS has to check that the bus rose close to the pack voltage in the expected time, and stop if it didn’t, before closing the main switch. The resistor has to be rated for that pulse, not its average power, and retries into a fault add up, so limit them. Close the main switch only when the remaining difference is small: 1 percent of 58.8 V across 50 mΩ is still about 12 A. And keep the load’s converters off until the bus is up, or they draw through the precharge path and stall it below the pack voltage.
Thermal runaway spreading
A cell in thermal runaway heats its neighbours. The measures that stop it at one cell are spacing or barriers between cells, a vent path away from the other cells and the electronics, cell-level fusing so a shorted cell doesn’t keep drawing from its group, and an enclosure that contains what’s left. Propagation depends on the cell and the build, so test it in the real pack. IEC 62368-1’s battery annex has clauses on charging safeguards, a fire enclosure and a drop test for equipment containing secondary lithium batteries.
The 60 V line
60 V dc is where IEC 62368-1 stops treating a source as class 1 (ES1); class 2 runs to 120 V dc. It isn’t a universal touch-safe voltage: other standards put extra-low voltage at up to 120 V ripple-free dc, and the ITU notes that the 60 V ES1 level “is not directly equivalent to an ELV touch voltage value of 60 V”. IEC 62368-1 covers audio, video, information and communication technology equipment up to 600 V; vehicle, industrial and medical products fall under other standards.
Work the pack out at its highest voltage, not at nominal: fully charged on the charger’s highest setting, and at the protection’s trip, which is what a failed charger leaves it at. A 14S lithium-ion pack is 50.4 V nominal and 58.8 V full; 15S at 4.2 V is 63 V; 14S of 4.35 V high-voltage cells is 60.9 V. A 16S LiFePO4 pack at 3.65 V per cell is 58.4 V. At the 4.28 V overcharge threshold in the protection article, 14S is 59.9 V, with almost no margin left. One more cell, or a higher charge voltage, moves a design across the line.
Transport and safety testing
UN 38.3 applies to batteries as well as cells, so a pack is tested as a pack: up to eight tests, in IATA’s summary, including altitude simulation equivalent to 15,200 m for 6 hours and thermal cycling between 72 °C and −40 °C. Lithium-ion batteries shipped on their own must be at no more than 30 percent of rated capacity, and from 1 January 2026 the same applies to batteries packed with equipment. Which safety standards apply where is in compliance by market, and in the EU the replaceable-battery rules affect how a pack is fitted and removed.
Checks before layout
- Charge stops or slows on the highest cell, with the monitor’s error over temperature in the budget.
- The bleed current, at its real duty, removes the drift each cycle and the one-off offset in a stated number of charges.
- LiFePO4: balancing happens on the rise at the top of charge, never on mid-plateau voltage.
- Parallel cells are matched in resistance as well as capacity, and brought to the same voltage before joining.
- Cell-level fusing, if used, opens on a shorted cell’s fault current and survives normal current.
- Open sense wires are detected and stop the charge.
- The switches open on per-cell limits with the host crashed.
- Precharge times out if the bus doesn’t rise, and closes only when the bus is close to the pack.
- The highest pack voltage, full on the highest charger setting, is checked against 60 V.
- UN 38.3 is planned for the pack, not only the cells.
If you’re working out a multi-cell pack’s monitoring, balancing or protection, or want a second look at one before it’s built, get in touch.