Why a lithium charger never finishes or stops early: thresholds and tolerances
A lithium charger that never finishes, or stops early, is usually doing what its settings tell it to: a threshold has landed somewhere inside its tolerance band, and the design didn’t allow for where. It never finishes when termination sits below what it can resolve, when termination is suspended because it’s limiting the current, or when a system load hides the end of the taper; it stops early when termination is set high, the safety timer is short, or the protection trips at the top. Charger chips hold the charge voltage to about ±0.5 to ±1 percent, 21 to 42 mV at 4.2 V, against a cell whose limit may be 4.20 V ± 0.05 V. Termination is often a tenth of the charge current, ±10 percent or more, against the cell maker’s 0.02C to 0.05C, and at a setting of about a milliamp it can be off by ±60 percent. The charger also sees the cell through switches, connectors and traces whose drop moves it into constant voltage early and stretches the taper. Work every control point at its worst case: the charge voltage at its maximum against the cell’s limit, the termination current at its tolerance against the current the charger actually measures, and the safety timer against the slowest real charge.
In practice: set termination to the cell datasheet’s cutoff, usually 0.02C to 0.05C, and check that the charger can resolve that current at its worst tolerance. Choose the charge voltage so that the charger’s maximum, not its typical, stays under the cell’s limit: on a 4.20 V ± 0.05 V cell, a ±0.5 percent charger leaves 29 mV of margin and a ±1 percent charger leaves 8 mV.
The terms are defined in How lithium-ion charging works; this article puts tolerances on its numbers. A charger that’s fine on the bench, with one cell at room temperature and nothing else connected, meets every corner of those tolerances in production.
The mistake I see most isn’t a wrong number. It’s setting each control point as if it were one number: the trickle rate and the threshold that ends it, the charge voltage, the termination current, the recharge point, the temperature limits. Count the parts’ tolerances, the cell’s temperature and whatever the system is drawing at the time, and each one becomes a band. The charger has to do the right thing at both edges of every band, not just at the typical value it was designed around.
The control points
Every lithium charger has these settings, whether a chip holds them or firmware does. The ranges are the spread across several charger and protection chip families and cell datasheets, not limits for any one part; the cell’s own datasheet overrides them.
| Control point | Range across chargers and cells | Set by | Charger-side tolerance | When it’s off |
|---|---|---|---|---|
| Precharge threshold | 2.4 to 3.1 V across chargers, tolerance included (lithium-ion); about 2.0 V (LiFePO4) | Chip option, register or firmware | Included in the range; up to about ±0.2 V | Too high, a healthy cell crawls; too low, full current into a damaged cell |
| Precharge current | Often 10 to 20 percent of fast charge (options up to 40) | Resistor ratio, register or DAC | ±10 to ±56 percent | A load on the cell can take all of it |
| Battery-short (deep-discharge) threshold | 1.6 to 2.35 V (lithium-ion), about 1.2 V (LiFePO4); below it 4 to 110 mA, or nothing | Charger chip, protection circuit | — | Decides whether a cell near 0 V is charged at all |
| Fast-charge current | Standard 0.2C to 0.5C (energy cells), maximum often 1C; about 2C for some power cells | Resistor and chip gain, register or DAC | ±5 to ±20 percent, worst at low settings | High corner over the cell’s maximum; low corner toward the timer |
| Charge voltage | 4.2 V; 4.35 or 4.4 V (high-voltage); 3.6 to 3.65 V (LiFePO4) | Chip option, register, or divider and reference | ±0.5 to ±1 percent; ±0.8 percent over temperature on one chip | Above, past the cell’s limit; below, capacity left unused |
| Termination current | Cells 0.02C to 0.05C (0.01C on one LiFePO4 sheet); chips often a tenth of the charge current | Ratio to charge current, register or firmware | ±10 to ±25 percent; ±60 percent at 1 mA on one chip | Never finishes, or stops early |
| Recharge threshold | About 60 to 265 mV below the charge voltage, more on chargers that set it as a percentage | Chip option or register | ±25 to ±50 mV; about ±105 mV on one chip that sets it as a percentage | Too close, micro-cycles near full; too far, sits well below full |
| Hysteresis | About 200 mV on precharge and deep-discharge thresholds (one chip) | Chip or firmware | — | The charger chatters between states |
| Safety timers | Precharge 30 minutes to 4 hours; fast charge 5 to 20 hours nominal | Resistor, register or firmware | ±5 to ±20 percent; some count at half rate while limiting | Too short ends a slow charge; disabled, nothing ends a stuck one |
| Input current limit | 100 mA to over 3 A, matched to the source | Pin, register or source detection | One-sided: 440 to 500 mA at a 500 mA setting (one chip) | Less charge current; termination suspended |
| Input voltage regulation | About 4.4 to 4.5 V on a 5 V input | Chip option or register | About ±3 percent | A weak source pulls the charge current down |
| Charger thermal limit | Die at 90 to 125 °C | Chip or register | — | Current folds back; termination suspended |
| Cell temperature window | Often 0 to 45 °C, cell-specific | Thermistor network | Thermistor and comparator tolerance | Charge paused or reduced |
Working the tolerances
Charge voltage against the cell’s limit
Take a cell whose datasheet gives an end-of-charge voltage of 4.20 V ± 0.05 V, so 4.25 V is the most it may see. One linear charger family specifies its regulation voltage as 4.16 V minimum, 4.20 V typical and 4.23 V maximum. At the maximum, the margin is 4.25 − 4.23 = 20 mV. A ±1 percent charger can reach 4.2 × 1.01 = 4.242 V, leaving 8 mV; a ±0.5 percent one, 4.221 V and 29 mV. The JEITA guideline gives 4.25 V as the upper charging voltage for cobalt-type cells, and a chip maker’s note on the guideline makes the same point: that 4.25 V includes the charger’s full tolerance.
Use the full-temperature figure: one family holds ±0.5 percent at 25 °C but ±0.8 percent from −40 to 125 °C junction, a top of 4.2 × 1.008 = 4.234 V.
High-voltage cells are tighter, because their charge voltage is often an absolute maximum. One 4.35 V pouch cell’s datasheet says charging beyond 4.35 V per cell must be strictly prohibited. A charger set to 4.35 V at ±0.5 percent can reach 4.35 × 1.005 = 4.372 V, 22 mV over. Keeping the worst case at 4.35 V means a setting of 4.35 / 1.005 = 4.328 V at ±0.5 percent, or 4.35 / 1.008 = 4.315 V at ±0.8 percent, and a charger whose setting can land there: programmable chargers set the voltage in steps, 16 or 32 mV on three read, so the usable setting is the nearest step at or below the target. If the protection also has to fit under that maximum, the setting goes lower still, as the protection article works out. At the low corner the 4.328 V setting gives 4.328 × 0.995 = 4.307 V, 43 mV under the cell’s maximum, and that’s where to judge the capacity cost; the cell maker’s capacity at the lower voltage says how much. As a guide only, one study of the cathode material measured 165 mAh/g at 4.35 V and 160 mAh/g at 4.30 V, about 3 percent for 50 mV.
The protection circuit’s overvoltage threshold must never trip in a normal charge. Two pack protection circuits for 4.2 V cells give 4.28 V ± 25 mV (4.255 V at the bottom) and 4.26 V minimum: 25 to 30 mV above the 4.23 V charger, 13 to 18 mV above a ±1 percent one. A single-cell protection chip family offers overvoltage thresholds in 50 mV steps with ±20 mV accuracy from 0 to 60 °C, so its 4.25 V option can trip at 4.23 V, exactly where that charger may regulate. Some packs add a secondary overvoltage protector above that, an independent circuit that blows a fuse or disables the pack for good; its thresholds start around 4.30 V. Charger, cell limit and primary protection all fit inside about 100 mV, and at the end of charge, with little current flowing, the charger’s pin and the protection’s cell reading are nearly the same voltage.
When firmware measures the voltage
A charger chip’s reference and divider are trimmed in the factory. A discrete charger, or one where firmware decides the end of charge, measures through a resistor divider into an ADC with its own reference.
The divider alone can break the budget. Take an example 9:1 divider, ratio 0.1, built from 1 percent resistors. At the worst corner, top resistor 1 percent high and bottom 1 percent low, the ratio is 0.99 / (9 × 1.01 + 0.99) = 0.0982, 1.8 percent low. The firmware reads 1.8 percent low and charges 1.8 percent high: at 4.2 V per cell, about 76 mV over, past the cell’s 4.25 V limit and into the protection band. On a series pack, it’s the same 76 mV in every cell’s share.
A larger division ratio makes it worse, since the error tends toward the sum of the two resistor tolerances, and that’s initial tolerance only; temperature coefficient and drift add to it, while matched resistors reduce it. Then come the ADC’s gain and offset errors and the reference’s accuracy and drift, and the reference is often the largest term, especially when it’s the processor’s own supply rail. On the examples read, one microcontroller’s internal reference is specified at ±1.5 percent, which is 63 mV at 4.2 V on its own; one wireless chip’s ADC gain error is −3 to +4 percent; and a separate voltage reference is 0.2 percent initial with up to 50 ppm/°C of drift. A high-impedance divider also needs time to charge the ADC’s sampling capacitor, and a reading taken during charger ripple adds its own error. Tighter resistors, calibration against a reference meter, or both, get a firmware charger into a 20 mV budget, and the calibration has to hold over temperature. On a series pack, regulating the total doesn’t stop one cell going over, which is what per-cell monitoring is for.
The current measurement has a low end too. A firmware charger that terminates on measured current sees 50 mA through a 10 mΩ shunt as 0.5 mV, so an amplifier or ADC offset that’s negligible against the full charge current can be most of the termination signal, along with the shunt’s tolerance and temperature drift. That’s a common reason a firmware charger fails to terminate.
Charge current: the resistor and the gain
On many charger chips one resistor sets the fast-charge current: current = K / R, where K is the chip’s gain factor in ampere-ohms. The resistor is what people check, but the gain is usually the bigger term.
One family gives K as 797 minimum, 890 typical and 975 maximum. With R = 890 Ω (an example value; the nearest standard value is 887 Ω) for a nominal 1.000 A and a 1 percent resistor (881.1 to 898.9 Ω), the current lands between 797 / 898.9 = 0.887 A and 975 / 881.1 = 1.107 A, −11 to +11 percent, of which the resistor contributes 1 percent. Another family’s K is 300 ± 10 percent, and its datasheet gives 90 to 110 mA at a 100 mA setting. Register-set chargers aren’t automatically better: one specifies ±20 percent at 128 mA, ±10 percent at 256 mA and ±5 percent at 1,792 mA.
Both corners matter. Against a cell rated for 1C maximum, a 1C nominal setting reaches 1.11C, so the nominal comes down to about 0.9C. At the low corner the current is 11 percent under and the constant-current phase runs about 13 percent longer; with the nominal already brought down to 0.9C, the low corner is about 0.8C, a quarter longer than a timer sized for 1C allows for. The same tolerance applies to reduced cold-weather currents (one cell asks for 0.25C below 10 °C). A precharge current set from the same resistor has its own, wider tolerance: ±20 percent on the family above.
Termination current at low settings
Termination has the widest tolerances, because comparator offset is a fixed error that grows as a share of a small threshold.
Cell makers state 0.02C to 0.05C: one 4,900 mAh cell uses 0.02C (98 mA) for its capacity rating and 0.05C (245 mA) for its cycle test. Chips that set termination as a ratio usually default to a tenth of the charge current, specified on two families as 0.09 to 0.11 and 0.085 to 0.115 times the charge current. At a 0.5C charge, a tenth of it is 0.05C nominal and 0.045C to 0.055C across the first family’s tolerance: at the top of the cell’s range or just above it. At a 1C charge it’s 0.09C to 0.11C: 4.5 to 5.5 times the 0.02C cutoff behind the cell’s capacity rating, and about twice its 0.05C cycle-test figure. The termination ratio is specified against the actual charge current, which has its own tolerance; if the two errors are independent, which depends on the chip, a 0.5C nominal charge can terminate anywhere from about 0.040C to 0.061C.
Absolute settings show the low end. One charger’s 1 mA termination is specified at 0.4 mA minimum and 1.6 mA maximum. As an example, on a 20 mAh cell charged at 10 mA (0.5C), the cell’s 0.02C to 0.05C is 0.4 to 1 mA, and the charger’s band runs from 0.02C to 0.08C. Another chip’s 60 mA setting is 45 to 75 mA, and its datasheet warns that offset can put low settings 10 to 20 mA above target, with a top-off timer to compensate. A third can’t be set below 64 mA, so 0.02C is out of reach on any cell under 3,200 mAh, and 0.05C on any cell under 1,280 mAh.
Too high a threshold stops with charge left in the cell; how much depends on the cell’s taper, and one chip maker’s application note puts a cell terminated at C/10 at only 90 to 95 percent of capacity. Too low, and if the charger can’t resolve it or the current never gets there, the charge never ends.
One board, different cells
Fitting two cell sizes to one charger design moves every ratio. As an example, 1 A of charge and 100 mA of termination is 1C and 0.1C on a 1,000 mAh cell, 0.33C and 0.033C on a 3,000 mAh one, and a timer sized for the small cell can cut the large one short. Spread within one cell type is small by comparison, though resistance grows with age and cold, so size timers and tapers for an old cell in the cold rather than a fresh one at 25 °C: 3,200 mAh minimum against 3,350 mAh typical moves a 0.02C threshold from 64 to 67 mA.
On large packs the same arithmetic is in amps. Across 10 to 25 Ah, 0.02C to 0.05C runs from 200 mA to 1.25 A, and the current measurement has to resolve the bottom of that while also measuring the full charge current.
Where the charger measures the voltage
A charger regulates the voltage where it measures it, usually its own output. Between there and the cell’s chemistry sit the cell’s internal resistance and the path: a current-sense resistor, the protection circuit’s two switches, a fuse, a connector, traces and leads.
As an example, with values picked for the arithmetic rather than taken from a datasheet: a 10 mΩ sense resistor, two protection switches at 10 mΩ each, 10 mΩ for the connector’s two contacts and 10 mΩ for traces and leads, 50 mΩ in all. Real parts can be higher: small wire-to-board connectors are specified at 10 to 30 mΩ maximum per contact, double that after wear, so two contacts alone can exceed the example’s whole budget. At 1 A the drop is 50 mV, at 2 A 100 mV, so with a 4.20 V setting the charger enters constant voltage when the cell’s terminals are at 4.15 V or 4.10 V.
That doesn’t overcharge anything; it slows the charge. In constant voltage the current is the difference between the charger’s voltage and the cell’s open-circuit voltage, divided by all the resistance in between. One 21700 cell’s datasheet gives a DC resistance of 30 ± 6 mΩ, so the example path takes the total from 30 to 80 mΩ, about 2.7 times. In a simple model the constant-voltage phase stretches roughly in proportion to that total. The 30 mΩ is a 30-second DC figure and the effective resistance over a long taper is higher, so 2.7 times is an upper bound. At a low termination current the final voltage barely moves: 50 mA through the 80 mΩ total is 4 mV. At a high one it does: a tenth of a 1C charge on a 3 Ah cell is 300 mA, and 300 mA through 80 mΩ leaves the cell 24 mV short of the setting. So the drop costs time at low termination currents and some capacity at high ones, provided the timer lets the charge finish.
The return path counts too: drop in the negative lead and the ground return shifts any reference or measurement made against local ground, just as the positive side does.
Sensing at the cell takes the drop out of the measurement: a separate pair of sense wires, carrying no charge current, to both cell terminals. A broken sense wire must not read low and let the charger drive its output up. A common arrangement is a resistor from each sense line to its force line at the charger end, so an open sense wire falls back to sensing locally, plus an independent output-voltage limit. Past a pack’s own protection switches, the charger can only sense if the pack brings out a sense connection.
Why it never finishes
A charge that never terminates is ended by the safety timer, if there is one, and reported as a fault or not at all. The usual causes:
- Termination below what the charger can resolve, or below its minimum setting.
- The charger is limiting. Charger datasheets suspend termination while thermal regulation or an input limit is reducing the current, since a reduced current would look like the end of the taper. A charger that stays in regulation never terminates, and one family also runs its timer at half rate meanwhile.
- Drop in the path. A long taper that the timer ends first.
- Temperature bands. Some chargers disable termination in the cool and warm bands of their temperature scheme.
- A standing current on the cell node. With termination set to a milliamp or so, a voltage divider, a regulator’s quiescent current, an indicator LED or the protection circuit’s own drain, a few hundred microamps between them, is a real share of the threshold, and a cell with high self-discharge or a soft internal short adds more.
- Dropout. A linear charger needs its input above the cell voltage by its dropout: one family drops 425 mV at 500 mA, so holding 4.2 V at that current needs about 4.63 V at the charger, against a USB port allowed to sag to 4.75 V before cable loss, or 4.40 V at configuration. In dropout the charger can’t reach its regulation voltage, and the current falls for a reason that isn’t the taper. Depending on the charger that ends in a timer fault or, where termination doesn’t wait for regulation, an early stop.
- A load drawing through the charger’s current measurement. The charger sees cell plus load, and a load at or above the termination threshold hides the end of charge.
A load on the cell is the most common of these, and the article on charging under load works through it: a continuous load at or above the termination current lets the cell reach full voltage and still never terminate.
Why it stops early
Stopping early is quieter, because the product reports full and nobody looks.
- Termination above the taper that matters: a tenth of a 1C charge current ends at 4.5 to 5.5 times the cell maker’s 0.02C capacity cutoff.
- A timer shorter than the slowest real charge. Two cell makers give 3 and 4.0 hours for their standard 0.5C charges. One charger family’s default fast-charge timer is 5 hours, 4 to 6 across its tolerance, so at its minimum it ends at exactly 4.0 hours. Paired with a termination near 0.02C, as those charge times assume, that leaves nothing for a current at its −11 percent corner, a weak source, foldback, or a cold or aged cell’s longer taper.
- A cold or aged cell. Its higher resistance means the current tapers to a fixed termination threshold at a lower state of charge, with no fault anywhere; the higher the termination ratio, the bigger the effect.
- Foldback near the termination threshold, on a charger that doesn’t suspend termination while limiting: it stops on a part-charged cell. A firmware charger has to suspend it on purpose. The timer has the same problem: one family runs it at half rate while limiting, but a timer that keeps full speed through foldback or a reduced cold-band current can end a charge that was only slow.
- Protection tripping at the top, if its overvoltage band overlaps the charger’s maximum. The pack disconnects and the charger sees an open circuit (below).
The opposite mistake is no timer at all. On one sample board the charger had no charge timer and its thermistor input was tied to a fixed resistor, so nothing would end a charge that never reached termination, or one in heat or cold.
Hysteresis, recharge and repeated top-ups
Every threshold needs hysteresis, a gap between the level that enters a state and the one that leaves it, or ripple, noise and load steps make the charger chatter. One chip moves from precharge to fast charge at 3.0 V rising and back at 2.8 V falling, and gives its deep-discharge threshold 200 mV of hysteresis. A firmware charger needs the same on every threshold, plus a time filter.
The recharge threshold is hysteresis at the top: after termination the cell relaxes, any load draws it down, and the charger restarts once it has fallen far enough. Its tolerance stacks with the charge voltage’s: on one family the charge voltage is 4.16 to 4.23 V and recharge starts 60 to 140 mV below it, so the restart point lies anywhere from 4.02 to 4.17 V. Another datasheet puts its restart at about 80 to 90 percent of capacity.
On a product that sits on its charger with a small load on the cell, a threshold too close to the charge voltage gives top-ups all day, and the cell spends its life at full voltage, where it ages fastest. A power path that runs the system from the input avoids most of it.
No cell, or a cell behind an open protection switch
With no cell, a charger’s output is just its capacitor, and what happens next depends on whether the charger looks for a battery. One family runs a detection routine: it pulls its output down below regulation with a small sink current and watches whether the voltage recovers, so a missing battery shows as a periodic dip on the output, and its status pin stays off. Another sources a few microamps and decides there’s no battery when its output rises above the regulation voltage. A charger without detection reaches its regulation voltage at once, sees the current fall to nothing, reports complete, and cycles as the capacitor’s voltage decays to the recharge threshold, with the status blinking between charging and complete. A switching charger’s loop is designed around a cell’s low impedance; without one the output can overshoot or oscillate. A pack that disconnects at full current dumps the inductor’s energy into the output capacitor, so the charger’s output, and anything else on that node, sees an overshoot.
A cell behind an open protection switch looks like no cell. After an overvoltage trip the protection waits for the cell to fall to its release voltage; after an undervoltage trip it needs the charger to apply a voltage first. A charger that sees no cell and stops driving its output can leave the two waiting for each other.
A cell near 0 V
Whether a cell near 0 V gets charged is a decision with three parties in it. The charger has a deep-discharge threshold, 1.6 to 2.35 V across the families above, below which it feeds 4 to 110 mA or nothing; 110 mA into a 20 mAh cell is 5.5C, far more than a damaged small cell should get. One single-cell protection chip allows zero-volt charging if the charger’s voltage is above 1.7 V. And the JEITA guideline advises against charging a cell that has fallen below its end-of-discharge voltage, because the negative electrode’s copper current collector can dissolve when a cell is driven down toward 0 V (see How lithium-ion charging works). Before blocking charging below a threshold, tell a cell near 0 V from a pack whose protection has opened and shows 0 V at its terminals with a healthy cell behind it. In a firmware charger, make that decision deliberately and write it down.
What the status output tells the user
A status output that shows only charging or not charging can’t tell full from a timer fault, a temperature pause, a cell stuck in precharge or no cell, and each needs a different response.
On one sample board, the fixed resistor for the thermistor pin was placed on the bottom side while the assembly notes ordered top-side parts only. Unfitted, the pin floated and the charger never charged. Whether a user could tell that from a flat battery depends on what the status output reports.
Decide which states the product shows (no power, charging, complete, fault), and power the fault indication from something that stays on when the protection has cut the output.
Worst case or statistical
Work anything that sits against a safety limit at its full worst case: the charge voltage against the cell’s limit, the charge current against the cell’s maximum, the protection thresholds against the charger. For things that only cost time or a little capacity, such as charge time against the timer, a root-sum-square of independent tolerances is a fair estimate, as long as the timer itself is set from the worst case. Then measure the charge voltage on every unit in production test, because a mistake in the stack-up or a wrong part shows up there and nowhere else.
The low corner deserves a look too. A charger at 4.16 V leaves each cell a little short of full, and its recharge point drops with it. If a fuel gauge reports the state of charge, its idea of full has to agree with the charger’s termination, or the product never shows 100 percent.
Checks before layout
- Charge voltage at its maximum over temperature against the cell’s limit, and protection overvoltage at its minimum against it.
- For firmware measurement: divider, ADC and reference errors added at the worst corner, and calibration if they don’t fit.
- Charge current at the gain’s high corner against the cell’s maximum, including cold-band and precharge currents.
- Termination at its tolerance, including the charge current’s, in C, against the cell’s 0.02C to 0.05C, for every cell size the board takes, and with every standing current on the cell node counted.
- Input voltage at its minimum, after the cable, against the charger’s dropout at full current.
- Resistance from the sense point to the cell; a broken sense wire fails safe.
- Safety timer at its minimum against the slowest real charge.
- Termination suspended while limiting and filtered against load pulses; no system load hiding in the current measurement.
- Hysteresis on every threshold, and the recharge threshold on a docked product.
- No cell, a mid-charge disconnect, a protection trip, a cell near 0 V: each with a decided behaviour and a status that shows it.
If your charger finishes on the bench but not in the field, or you’d like these tolerances worked for your cell and charger, get in touch.