Charging LiFePO4: how it differs from lithium-ion
LiFePO4 (lithium iron phosphate) cells charge the same way as other lithium-ion cells, constant current and then constant voltage, but to 3.6 to 3.65 V per cell instead of 4.2 V, and the charge ends when the current tapers to between 0.01C and 0.05C, depending on the cell. A “12 V” LiFePO4 battery is four cells in series, 12.8 V nominal, and battery makers set its absorption voltage between 14.2 and 14.6 V. Its voltage sits on a nearly flat plateau for most of the charge, so voltage says little about how full it is, and a series pack can only be balanced on the steep rise at the very top. A lead-acid charger is safe on it only when it’s set up for it: absorption to the battery maker’s figure, 14.6 V at most including the charger’s tolerance, equalization and desulfation off, temperature compensation off, float off or at the maker’s float voltage, and no charging below freezing.
I’ve designed chargers for both chemistries, from small rechargeables to large packs.
A designer moving a product from nickel-based lithium-ion to LiFePO4 finds that several thresholds besides the charge voltage were tied to the chemistry. Someone fitting a 12 V LiFePO4 battery in place of lead-acid inherits a charger built for a different chemistry, and a battery whose own management system switches it off when it disagrees. The CC/CV phases and the terms are in How lithium-ion charging works.
What changes from nickel-based lithium-ion
The phases are the same: precharge for a deeply discharged cell, constant current, constant voltage, termination. The numbers at each control point move.
| Control point | Nickel-based lithium-ion | LiFePO4 |
|---|---|---|
| Charge voltage per cell | 4.2 V; 4.35 or 4.4 V for high-voltage cells | 3.6 to 3.65 V |
| Termination current (cell sheets) | 0.02C to 0.05C | 0.01C to 0.05C |
| Nominal voltage | about 3.6 V | 3.2 to 3.3 V |
| Discharge cut-off | 2.5 V on many sheets | 2.5 V; 2.0 V at or below 0 °C on two prismatic cells |
| Precharge threshold (charger) | 2.4 to 3.1 V across chargers, tolerance included | about 2.0 V |
| Battery-short threshold (charger) | 1.6 to 2.35 V | about 1.2 V |
| Recharge threshold (charger) | typically 100 to 200 mV below the charge voltage | 200 mV below, or 93 percent of the charge voltage, on two chargers |
| Charge temperature | often 0 to 45 °C, up to 60 °C on some power cells | 0 °C lower limit on most sheets; upper limit 45 to 60 °C |
| Float | none | 3.5 V from one cell maker; none from the others |
On a charger with a chemistry setting, those values move together, and it’s worth checking that they all did. On one small linear charger, choosing LiFePO4 moves the precharge threshold from about 2.8 V to about 2.0 V, the battery-short threshold to about 1.2 V and the recharge window from 100 to 200 mV, while precharge stays at 20 percent and termination at 10 percent of the set current. A larger multi-cell charger sets its thresholds as ratios of the charge voltage, and its maker recommends different ratios for LiFePO4: a low-battery threshold of 55 percent instead of 66.7 percent, and recharge at 93 percent instead of 97.6 percent. At 3.6 V per cell, the defaults would put those at 2.40 V and 3.51 V, against 1.98 V and 3.35 V for the recommended settings. A pack with one ratio left at its lithium-ion value still charges, so the mistake can survive the bench. With a default 3.51 V recharge point the charger restarts almost as soon as a full cell rests, since that’s above where the cell settles. Leaving the charge voltage itself at a lithium-ion setting is worse: 4.2 V is 0.55 V above a LiFePO4 cell’s 3.65 V.
Which charge voltage
The cell sheets read give 3.65 V as the cut-off on two large prismatic cells and a 10 Ah cell, 3.65 ± 0.03 V on one 18650, and 3.6 V on one 26650 power-cell family. One charger’s application note puts the regulation voltage for LiFePO4 at about 3.5 to 3.65 V, and one charger offers 3.5, 3.6 and 3.7 V. The 3.7 V option is above every cell sheet read, so it’s a setting to rule out, not choose.
Tolerance decides between the other two. A charger of that class holds its charge voltage to ±0.5 percent at 25 °C and ±0.8 percent over its junction temperature range. Set to 3.65 V, a charger with that tolerance can deliver up to about 3.68 V; set to 3.6 V, at most about 3.63 V, inside a 3.65 V limit. What the lower setting costs in capacity is cell-specific: measure it at the product’s own termination current. The full tolerance budget is in the article on control points and tolerances.
Termination
Charger chips commonly terminate at a tenth of the set charge current, while LiFePO4 cell sheets ask for 0.01C to 0.05C. At a 0.5C charge, a tenth is 0.05C, the top of the cells’ range; at 1C it’s 0.1C, above every LiFePO4 sheet read. One multi-cell charger warns that at low termination currents its comparator offset can stop the charge at up to 20 percent above the target, and offers a top-off timer, off by default, that keeps the constant-voltage phase going after termination.
Small stop currents are also easy for a load to hide. One 26650 power cell terminates at 3.6 V below 50 mA, about 0.02C. A product drawing 50 mA from the cell during the constant-voltage phase keeps the charger’s current from ever falling to that, so the charge ends on the safety timer instead, with the cell held at full voltage until then. The system-load cases are in the article on charging while the device is on.
The flat curve, and the knee at the top
Most of a LiFePO4 cell’s capacity sits on a plateau. One gauge maker’s table for one LiFePO4 cell puts 34 to 93 percent state of charge between 3,274 and 3,351 mV at rest, about 1.3 mV per percent on average; a standard lithium-ion cell’s flattest stretch, 26 to 54 percent, averages about 2.3 mV per percent and the rest of its curve is steeper. Above the plateau, on charge, the voltage climbs quickly to the charge voltage: while charging, the last few percent take the cell from the top of the plateau to the 3.6 to 3.65 V the charger holds. That’s terminal voltage under current: at rest, a full cell settles back much lower, a little above the plateau’s 3.35 V.
The shape matters to the charger in three places. Termination still works, because it’s measured on current during the constant-voltage phase, not on voltage. The recharge threshold doesn’t sit where it seems to: 3.4 V or 3.35 V, the two chargers’ settings at 3.6 V, are at the top of the plateau, so a full cell relaxing at rest can fall to its recharge threshold having given up almost no charge, and the charger restarts. In the other direction, the threshold’s own tolerance, ±25 mV on one charger, is about ±19 percent state of charge on the plateau’s average slope. Measure how far your cell falls at rest, and under the product’s real load, before settling the threshold.
Third, voltage can’t stop a charge partway. Holding a nickel-based cell at 80 percent by lowering the charge voltage is workable; on LiFePO4 one charger maker’s application note calls it essentially impractical, because “even with a charge voltage accuracy of +/-0.5%, you can be losing up to 41.4% of the battery’s available capacity”. A limit on LiFePO4 has to come from counting charge, which is also how its percentage has to be measured; one gauge maker’s note flags the difficulty when the battery can’t be fully discharged and rested for several hours. Gauging has its own article.
Series packs: everything happens at the top
A series pack’s charger controls the sum of the cell voltages, not each cell. On the plateau, cells at different states of charge sit within millivolts of each other, so a difference in charge barely shows. At the top it shows all at once: the cell that’s ahead reaches the knee first and its voltage rises steeply while the others are still on the plateau.
The pack voltage doesn’t limit that cell. In a four-cell pack held at 14.6 V, three cells still at 3.40 V leave 4.40 V for the fourth. Long before that, the battery’s own per-cell overvoltage protection should open, which is why one battery maker warns that a charger left on a flooded lead-acid setting, with its higher voltages, can make the battery’s BMS restrict charging. A lower absorption voltage, such as the 14.2 V one battery maker recommends, which is 3.55 V per cell, helps a little, but three cells at 3.40 V still leave 4.0 V for the fourth; only per-cell protection limits a leading cell. How protection thresholds and their tolerances are set is in the article on protection circuits; take LiFePO4 trip values from the cell or battery maker.
Balancing has to happen on that same knee. A cell monitor accurate to ±15 mV can’t place a LiFePO4 cell on the plateau better than about ±11 percent on average, so balancing on mid-plateau voltage moves charge on noise. Balancing at the top works only if charges regularly reach it and stay there long enough for small bleed currents to act. One battery maker recommends an absorption time of 2 hours, and for batteries that rarely get a full charge, at least 2 hours a month for lightly cycled backup or UPS use and 4 to 8 hours a month for heavily cycled systems, “to allow the balancer enough time to properly balance the cells”. A charger that drops to float on reaching absorption voltage, or a product kept part-charged, gives a top-of-charge balancer little or no time.
Pack voltages follow from the cell count. At 3.65 V per cell, four cells are 14.6 V, eight are 29.2 V and sixteen are 58.4 V, just under the 60 V line discussed in the balancing article, and over it once the charger’s tolerance and the protection’s trip are counted; one battery maker’s 24 V and 48 V absorption settings, 28.4 and 56.8 V, are 3.55 V per cell.
Lead-acid chargers on a 12 V LiFePO4 battery
A lead-acid charger uses constant current, then holds an absorption voltage of 2.40 to 2.50 V per cell, and for standby drops to a float of 2.25 to 2.30 V per cell, compensated for temperature; those are sealed-battery figures at 25 °C. For a six-cell 12 V battery that’s 14.4 to 15.0 V absorption and 13.5 to 13.8 V float. Four LiFePO4 cells at 3.6 V are 14.4 V, so the numbers overlap at the low end of absorption, which is why a lead-acid charger often charges a LiFePO4 battery and why the battery makers’ answer is conditional. The failures are at the edges of the lead-acid profile.
| Setting | Lead-acid profile | What LiFePO4 battery makers ask for (12.8 V) |
|---|---|---|
| Absorption | 14.4 to 15.0 V (2.40 to 2.50 V per cell) | 14.2 to 14.6 V (3.55 to 3.65 V per cell) |
| End of absorption | the charger’s own time or current | termination at or below 0.05C (one maker); 2 hours (another) |
| Float | 13.5 to 13.8 V | off, or 13.3 to 13.8 V (3.33 to 3.45 V per cell) |
| Equalization, desulfation, repair modes | periodic, at raised voltage | off, in every maker’s guidance that addresses it |
| Temperature compensation | about −5 to −6 mV per cell per °C on cycle charge | off, or 0 mV/°C |
| Storage mode | lower holding voltage | set equal to float, if present (one maker) |
The absorption voltage is the first edge. At the top of the lead-acid makers’ range, 2.45 to 2.50 V per cell, a lead-acid absorption of 14.7 to 15.0 V is 3.675 to 3.75 V per LiFePO4 cell, above every cell sheet’s 3.65 V, and that’s before any imbalance between the cells. Settings meant for flooded batteries tend to run higher still, which is the case the battery maker above warns will trip the BMS.
Temperature compensation pushes the voltage up in the cold, exactly when LiFePO4 wants it lower. At about −5 mV per cell per °C, a lead-acid charger whose sensor reads 10 °C adds 0.45 V to a 14.4 V absorption, giving 14.85 V, or about 3.71 V per LiFePO4 cell; at 0 °C it’s 15.15 V, 3.79 V per cell, at a temperature where the cell mustn’t be charged at all. In that same 0 to 10 °C band, one LiFePO4 cell maker allows charging only to 3.60 V at a reduced 0.2C. Float is compensated too, so a 13.8 V float at 0 °C becomes about 14.25 V, an absorption-level voltage held continuously; and in the heat compensation lowers the voltage, undercharging the battery. Every battery maker whose guidance addresses it says to turn compensation off.
Equalization, desulfation and “repair” modes deliberately overcharge lead-acid; an equalization level of 16.2 to 16.5 V, as one distributor quotes, is 4.05 to 4.13 V per LiFePO4 cell, and one battery maker says “elevated charge voltages are unacceptable”. Check whether the charger runs one automatically, not only whether it has a menu entry.
Two more catches come from the battery’s BMS. After an under-voltage trip the terminals show little or nothing, and one battery maker warns that “chargers that require the detection of voltage at the battery terminals to charge may fail to wake the LFP battery”. And charge current has its own limit; one battery maker recommends 0.5C, which a charger sized for a large lead-acid bank can exceed on a smaller LiFePO4 battery.
The settings to confirm on any charger going onto a 12.8 V LiFePO4 battery:
- Absorption 14.2 to 14.6 V, to the battery maker’s figure; on a charger with a separate bulk setting, set bulk to the same value.
- Absorption long enough to balance, or a way to give the battery its monthly balancing time.
- Float off, or at the battery maker’s float voltage; storage mode, if any, at the float voltage.
- Equalization, desulfation and repair modes off, including automatic ones.
- Temperature compensation off, or set to 0 mV/°C.
- Charge current within the battery’s rating, and a charger that will start into a battery reading near 0 V, or a documented way to wake it.
- No charge below the battery maker’s low-temperature limit: confirm the battery’s BMS blocks it, or block it in the charger. A lead-acid charger won’t stop for cold.
- With float off, where the charger restarts: a lead-acid re-bulk point is low on the LiFePO4 curve, so the battery may be mostly empty before it recharges.
I’d read those voltages out of the charger’s manual, or measure them, rather than trust a mode called “lithium”: the presets differ, from 14.2 to 14.6 V, with float on or off, and the name doesn’t say which.
Standby and UPS: float or stop and recharge
A nickel-based lithium-ion cell gets no float: the charger terminates and waits for the voltage to fall to a recharge threshold. LiFePO4 standby can be done the same way, or the cell can be held at a reduced voltage. One cell maker lists a float of 3.5 V, 100 mV below its 3.6 V charge, and describes its cell as suited to stand-by applications needing “stable float reliability”. Battery makers who give a float for 12.8 V batteries set 13.3 to 13.8 V, 3.33 to 3.45 V per cell; others prefer no float at all, and one calls it unnecessary. The makers differ by up to 0.5 V, so there’s no single LiFePO4 float voltage.
13.5 V is 3.375 V per cell, just above the 3,351 mV at which the gauge table above puts 93 percent, so a float at 13.5 V or more holds the cell near full rather than at some middle level, though the margin is less than a typical charger’s tolerance, and 13.3 V is on the plateau. Whether that shortens life is the gap in the evidence. There’s no published cell-maker or peer-reviewed curve of LiFePO4 life against float voltage to design to. The nearest data is storage at rest. In one open study, a LiFePO4 18650 stored full for nine months lost about 6 percent of its capacity at 25 °C against about 3 percent part-charged, and about 15 against 11.5 percent at 50 °C; the loss stepped up above about 70 percent charge and didn’t grow further toward 100 percent, unlike the nickel-manganese-cobalt cell in the same test. That’s storage at rest, not a float, so it hints at the answer without settling it.
A standby product still needs full charges. The balancer only works at the top, so a float that never reaches absorption leaves the cells to drift, which is why the battery maker above asks for at least 2 hours of absorption a month even for backup and UPS use. A gauge needs a full-charge reference too. And warmth costs more: in the same storage study the LiFePO4 cell kept full lost about 9.5 percent at 40 °C against 6 at 25 °C.
The system load decides how either scheme behaves. With a float, the charger supplies the load and the battery sits; without one, a load on the battery discharges it between recharges, so it cycles shallowly near the top for as long as it’s plugged in. A power path that feeds the load from the input and leaves the battery idle avoids that.
12 V and 24 V drop-in batteries
A 12.8 V drop-in battery is four LiFePO4 cells in series, a 25.6 V one eight, each with a BMS inside: per-cell monitoring, balancing, temperature sensing and switches that disconnect the cells for charge, discharge or both. The charger sees none of it, only a battery that accepts current until it suddenly doesn’t.
The BMS opens for reasons the charger can’t predict:
- A cell over voltage, usually the leading cell on the knee, while the pack voltage still looks normal.
- Temperature, if it has a low-temperature charge cutoff; not every drop-in does, so check: one battery maker’s table forbids charging at 0 °C or colder and reduces current up to 10 °C, and another allows charging only from 5 to 50 °C, while both still allow discharge below freezing.
- Under-voltage after a deep discharge, which leaves the terminals near 0 V and some chargers unwilling to start.
- Overcurrent, on charge or discharge.
In a vehicle, that disconnect has a particular consequence. The load dump in ISO 16750-2 is defined by the battery disconnecting while the alternator is charging it, and where the drop-in battery is the only battery on the alternator, its BMS opening the charge path with the engine running is that event, on a supply designed with a lead-acid battery as its buffer. A starter battery left in parallel, or a DC-DC charger between the alternator and the LiFePO4 battery, takes it instead. The battery’s low resistance can also hold an alternator at full output for long periods, which is another reason a DC-DC charger is the usual answer. The test levels are in the article on charging from multiple sources; read the battery and vehicle makers’ guidance on alternator charging before fitting one.
Cold and heat
LiFePO4 doesn’t escape the lithium-ion rule on cold charging. Most cell sheets read forbid charging below 0 °C; one power cell allows under 250 mA there, about 0.1C, “for some applications”; one prismatic maker lowers both the current, to 0.2C, and the voltage, to 3.60 V, from 0 to 10 °C, and where one sheet’s tables disagree, the stricter row governs. Upper charge limits run from 45 °C on several sheets to 55 or 60 °C on others, and the battery makers’ own limits are stricter at the cold end than the cells’. Discharge is allowed much colder, to −20 °C on one charger maker’s comparison and one battery maker’s manual.
The charge window, thermistor placement and tolerance, and what a charger with its thermistor input tied off does in the cold are in the article on charge temperature limits.
Life and storage against nickel-based cells
LiFePO4’s long cycle life shows most in deep cycling. In a national laboratory study of commercial 18650 cells, capacity faded faster with deeper cycles in every type, but the nickel-cobalt-aluminium and nickel-manganese-cobalt cells were much more sensitive to full-range cycling than LiFePO4. The same study found LiFePO4 fading faster as the temperature rose from 15 to 35 °C, so heat costs it cycle life as well as calendar life.
Storage advice from the cell makers puts LiFePO4 part-charged: 30 to 50 percent, or 3.0 to 3.3 V, and above 2.9 V, on one maker’s sheet; 3.3 to 3.4 V with a recharge every six months on another’s. Those voltages are on the plateau. On the gauge table above, 3.3 to 3.4 V spans everything from somewhere in the middle of the plateau to above 93 percent, and a second LiFePO4 cell in the same table spans 12 to 92 percent between 3.193 and 3.329 V, so without that cell’s own rested curve a storage voltage can’t tell you the cell is at 30 percent rather than 80. Set a storage or shipping charge by counting it, from full or from empty, not by voltage. LiFePO4 ships as lithium-ion, so the air-shipping limit of 30 percent applies; it and the shelf-drain arithmetic are in Making lithium batteries last.
Self-discharge isn’t a reason to choose LiFePO4. One LiFePO4 maker specifies at most 3 percent a month at 25 °C, stored at 30 to 50 percent, and another’s cell keeps at least 90 percent after 30 days from full; nickel-based makers give 2 to 3 percent a month. No maker’s figure here is lower for LiFePO4. A drop-in battery’s BMS also draws from the cells continuously, so a season on a shelf needs that drain counted against the 2.9 V floor.
If you’re moving a product to LiFePO4, or putting a LiFePO4 battery behind a charger built for lead-acid, and want the thresholds and settings checked against the cell and battery datasheets, get in touch.