How much current can a device draw from USB and USB-C?
Rules change often. Check before you rely on this. This article is an engineer's summary, not legal advice. Confirm the current rules for your product and markets before you commit to a design or a test plan.
A USB 2.0 device may draw 100 mA until the host configures it, then up to 500 mA; on single-lane USB 3.x the steps are 150 mA and 900 mA (1.5 A on dual-lane), and any suspended device is held to 2.5 mA. A Battery Charging 1.2 port lets a portable device draw up to 1.5 A. A USB Type-C source advertises Default USB Power, 1.5 A or 3.0 A at 5 V through a pull-up on its CC pin, which the sink reads through its 5.1 kΩ pull-downs. USB Power Delivery negotiates more: fixed 5, 9, 15 and 20 V at up to 3 A, or 5 A at 20 V with a 5 A cable, for up to 100 W, and in its extended power range 28, 36 and 48 V at up to 5 A, for up to 240 W. Every step above the unconfigured current is something the device has to ask for or detect.
A charger set to 1 A on a port that has promised 100 mA pulls the port down, and the device resets or charges at a crawl. The charging phases are in How lithium-ion charging works, and sharing the input between system and cell is in the power path article; this one is about the port.
What each source allows
| Source | Voltage | Current the device may draw | What the device has to do to get it |
|---|---|---|---|
| USB 2.0, before configuration | 4.75 to 5.25 V at a high-power port (5.5 V maximum after a later change) | 100 mA (one unit load) | Connect; a device that never connects is suspended |
| USB 2.0, configured | As above | Up to 500 mA (five unit loads) | Enumerate and be configured |
| USB 3.x, before and after configuration | 4.75 to 5.5 V | 150 mA, then up to 900 mA (six unit loads), single-lane; 1.5 A dual-lane | Enumerate and be configured |
| Any USB port, bus suspended | 2.5 mA | Cut back on suspend | |
| Battery Charging 1.2 charging downstream port | 4.75 to 5.25 V | Up to 1.5 A, with data | Detect the port type on D+ and D− |
| Battery Charging 1.2 dedicated charging port | 4.75 to 5.25 V up to its rating; may fall to 2.0 V between 0.5 and 1.5 A | Up to 1.5 A, no data | Detect the D+ to D− short |
| USB Type-C, Default USB Power | 5 V (4.75 to 5.5 V) | 500, 900 or 1,500 mA by port type | Present Rd; follow that bus’s configuration rules |
| USB Type-C, 1.5 A | 5 V (4.75 to 5.5 V) | 1.5 A (7.5 W) | Read CC through a ±10 percent Rd; follow changes |
| USB Type-C, 3.0 A | 5 V (4.75 to 5.5 V) | 3.0 A (15 W) | As for 1.5 A |
| USB PD fixed, standard power range | 5 V (4.75 to 5.5 V); 9, 15, 20 V ±5 percent, the higher voltages from higher-power sources | 3 A; 5 A at 20 V with a 5 A cable; 100 W at most | Negotiate on CC; stay inside the contract |
| USB PD programmable (PPS, R3.3) | 5 to 11, 5 to 16 or 5 to 21 V in 20 mV steps | Typically 3 A; up to 5 A with a 5 A cable | Negotiate voltage and current, and re-request periodically; optional for sources |
| USB PD extended power range (EPR) | 28, 36, 48 V fixed; adjustable from 15 V | Up to 5 A, 240 W | Enter EPR mode and keep it alive; EPR-capable cable; port above 100, 140 or 180 W |
Two entries are often misquoted. The Battery Charging 1.5 A is what a portable device may draw; the port itself may be rated 1.5 to 5 A (charging downstream) or 0.5 to 5 A (dedicated). And Type-C “Default USB Power” isn’t 500 mA by itself: the USB 2.0 or 3.x rules apply, so an unconfigured device stays at its unconfigured current. A port on a bus-powered hub is a further step down: low-power ports can sit as low as 4.40 V, where a device still has to be able to configure.
When several of these apply at once, the Type-C specification ranks them: a Power Delivery contract first, then a Type-C 1.5 A or 3.0 A advertisement, then Battery Charging 1.2, then the default.
USB 2.0 and 3.x: unit loads and configuration
USB 2.0 counts current in unit loads of 100 mA. Every device starts low-power, at one unit load, and becomes high-power, up to five, only under software control: the host reads the device’s descriptors and selects a configuration that declares the current. Single-lane USB 3.x uses a 150 mA unit load and up to six, 900 mA; dual-lane operation allows 1.5 A. The count is “an absolute maximum, not an average over time”, so a radio burst that peaks over the limit breaks it even when the average is well under.
A charger chip knows none of this: its input limit is a pin strap or a register. Hard-wired to 500 mA, it can draw five unit loads from a port that has agreed to one, and with no firmware to enumerate, the port never agrees to more. Some ports tolerate it, so the mistake can survive bench testing.
Suspend
When the host suspends the bus, every device may draw up to 2.5 mA, including the current through the bus pull-up and pull-down resistors. That figure came from a 2008 change to USB 2.0; the original 500 µA still appears in older documents and chip datasheets. For a charging product it means charging stops: something, usually the firmware, has to notice the suspend and turn the input limit down.
Inrush at attach
USB 2.0 and USB 3.2 both limit the capacitance a device presents on VBUS at attach to 10 µF, and USB 2.0 sets a target maximum droop of 330 mV on the hub’s VBUS. Power Delivery refers to the same attach limit, and allows 100 µF after a contract, more only behind current-limiting circuitry. In practice: no more than 10 µF at the connector, the bulk behind a soft-start or current-limited switch.
A cable plugged into a low-loss ceramic input capacitor can ring well above the supply, since the cable’s inductance and the capacitor form a lightly damped resonant circuit; one maker’s application note says the spike “can easily be twice” the applied voltage. The input’s rating, or a clamp, has to cover the peak, and on a PD sink that means the peak of the highest voltage it can be offered.
Battery Charging 1.2: ports that say so on the data lines
Battery Charging 1.2 adds two ports that supply more without enumeration: a charging downstream port, with data, and a dedicated charging port, with D+ shorted to D− through no more than 200 Ω. The device tells them from a standard port by driving and sensing small voltages on D+ and D−, then may draw up to 1.5 A. The charger usually does this in hardware, before any firmware runs, which is how a flat device with a blank processor charges at more than 100 mA from a charging port. So D+ and D− on a charging-only product aren’t optional: unconnected, they detect nothing.
Under load, a charging downstream port has to hold at least 4.75 V at 1.5 A, but the compliance test only asks a dedicated charging port to hold 2.0 V between 500 mA and 1.5 A. A weak adapter may let its voltage fall a long way; a charger with input-voltage regulation copes by backing its current off until the input stops falling.
USB Type-C: the advertisement on CC
A Type-C source puts a pull-up, Rp, on its CC pin, and a sink puts a 5.1 kΩ pull-down, Rd, on each of its two CC pins. The source sees Rd and turns on VBUS, and the divider’s voltage on CC tells the sink how much current is on offer. Rp can be a current source or a resistor:
| Advertisement | Current source | Pull-up to 4.75 to 5.5 V |
|---|---|---|
| Default USB Power | 80 µA ±20 % | 56 kΩ ±20 % |
| 1.5 A at 5 V | 180 µA ±8 % | 22 kΩ ±5 % |
| 3.0 A at 5 V | 330 µA ±8 % | 10 kΩ ±5 % |
Rd’s tolerance decides whether the sink can read the level. A 5.1 kΩ ±20 % resistor, or a voltage clamp, is enough to be seen; a sink that detects the advertised current needs ±10 %. With the current-source pull-up:
- Into a ±10 % Rd (4.59 to 5.61 kΩ), the default level lands between 0.29 and 0.54 V, the 1.5 A level between 0.76 and 1.09 V, and the 3.0 A level between 1.39 and 2.0 V.
- Into a ±20 % Rd (4.08 to 6.12 kΩ), those become 0.26 to 0.59 V, 0.68 to 1.19 V and 1.24 to 2.18 V. With a resistor pull-up it’s worse: the 1.5 A level can reach 1.25 V.
The specification’s bands for a ±10 % Rd are 0.277 to 0.612 V for Default, 0.746 to 1.164 V for 1.5 A and 1.369 to 2.042 V for 3.0 A, with the thresholds between them anywhere from 0.613 to 0.745 V and from 1.165 to 1.368 V. A ±20 % Rd pushes the 1.5 A level past the bottom of the upper threshold window and the 3.0 A level below its top, so a sink built that way can read 1.5 A as 3.0 A. That’s why the specification only lets a ±10 % Rd detect the level.
A sink taking more than the default has to keep monitoring CC and adjust its current within 60 ms if the advertisement changes. A multi-port charger can lower a port’s advertisement when a second device plugs in; a sink that read CC once keeps drawing 3 A. Under a Power Delivery contract the sink needn’t monitor the advertisement; the contract governs.
One resistor per CC pin
Each CC pin needs its own 5.1 kΩ to ground. A Type-C cable carries one CC wire, landing on one sink pin or the other depending on which way up the plug went in. In an electronically marked cable, the plug’s other CC position powers the marker and carries the cable’s own termination, Ra, 800 Ω to 1.2 kΩ. Share one resistor between the sink’s CC pins and that termination lands in parallel with Rd, giving under 1 kΩ, which the source reads as Ra rather than a sink, so with a marked cable the source may not recognise a sink and leaves VBUS off. The product charges from some cables and not others. With no Rd at all, a compliant source supplies nothing, a mistake on the list in what to check before you order an AI-designed board.
On a USB-C sink, the first thing I look at is the two CC resistors: one per pin, and a tolerance that matches what the charger or firmware expects to read from them.
Legacy cables and adapters
A Type-C to Standard-A cable connects the sink to a port with no CC pin, so the cable advertises for it with a 56 kΩ ±5 % pull-up, at Default USB Power, whatever the port can really supply. A sink that sees Default should still run Battery Charging detection on D+ and D−, since the port behind the cable may be a 1.5 A charging port, and assume only the unconfigured current until one of them says more. Non-compliant adapters (VBUS always on, 3.0 A advertised and a sag well before it) are handled by input-voltage regulation and an input limit that follows what was detected.
USB Power Delivery
Power Delivery runs a message protocol over CC: the source lists its capabilities, the sink requests one, and the accepted contract sets voltage and current. The standard power range has fixed 5, 9, 15 and 20 V at up to 3 A; a port above 60 W needs a 5 A cable, and 20 V at 5 A is the 100 W ceiling. A source offering more than 3 A has to query the cable’s marker and limit its offer to what the cable can carry, and every cable rated above 3 A is electronically marked, so 5 A needs a 5 A marked cable however the sink asks. Fixed supplies above 5 V are ±5 percent, and 5 V is 4.75 to 5.5 V. Not every source offers every voltage: the higher ones come only from higher-power sources, so a sink has to manage with 5 V when its preferred voltage isn’t there.
Sink-side limits from PD R3.3 for the design review:
- Bulk capacitance after negotiation: 100 µF at most, the rest behind current limiting.
- Current during a voltage transition, say 5 to 15 V: 500 mA at most.
- Load steps: no faster than 150 mA/µs.
- Survival: a sink should tolerate 24 V on VBUS without damage, even one that only ever asks for 5 V; an EPR sink, correspondingly more. The CC pins sit beside VBUS in the connector, so they need protecting against a short to it as well.
A standalone sink controller with a fixed request negotiates on its own; a firmware-driven port controller leaves the device on Type-C current until the firmware is up.
The sink has agreed to stay within the operating current it requested. An input limit set for a different adapter, or whose tolerance reaches above the contract, breaks that. The specification says a source’s over-current protection must not trip inside the contract, and that a source which detects an overload should hard-reset and renegotiate; it gives no trip threshold, so how far over a sink can go before that happens depends on the adapter. Set the input limit from the contract, with the top of its tolerance band under it.
Hard reset drops VBUS
A hard reset, the protocol’s restart after an error, takes VBUS away. The old contract holds for up to 15 ms; after 25 to 35 ms the source has up to 650 ms to bring VBUS to 0.8 V or less, while the sink draws no more than 1 mA; then the source waits 0.66 to 1.0 s and restores 5 V within 275 ms, at Type-C current until a new contract. From the maxima, VBUS can be below the contract for about 1.7 s, at or below 0.8 V for 0.66 to 1.0 s of it, and back at 5 V after about 2 s.
A product with a charged cell rides through on the battery. One running from the input with a dead cell can’t be held up: carrying 0.5 W through 0.66 s, from 9 V down to a regulator that needs 3.5 V, takes about 9.6 mF. The 100 µF limit is on VBUS itself, and more is allowed behind a current-limited switch, but 9.6 mF is a large capacitor for a small product, so most simply reset. The firmware then has to come back on Type-C current, renegotiate, and not provoke another reset. The protocol’s response timers are short, tens of milliseconds, and a late answer, a missed keep-alive or a failed voltage transition are among the timeouts that end in a hard reset, so a PD stack too slow after boot can loop.
Dead-battery operation
A system charged by USB whose battery is dead has to apply Rd to both CC pins and follow the sink rules, and then receives default VBUS. The unpowered circuit only has to hold CC within the range of the voltage-clamp form of Rd, and the clamp blocks PD messages; the system may start on the clamp and switch to the resistor once it can do PD. (A dual-role port, on a power bank say, may present at most 10 µF on VBUS while not sourcing.)
So what a dead device gets depends on how it’s built. On the clamp form of Rd it can’t read the advertisement, so it should assume Default USB Power. With discrete ±10 percent resistors and a charger that reads CC in hardware, it can take what the source advertises. A charger that runs Battery Charging detection on plug-in, as many do by default, can find a 1.5 A charging port. And a standalone sink controller powered from VBUS can negotiate PD before the processor runs. Boot, precharge and the charger’s start-up have to fit in whichever of those applies.
Back-feeding VBUS
A sink must not drive VBUS unless it’s the source, yet a battery switch, an on-the-go boost converter or a second power source can leak back onto it. A source expects VBUS near zero before it turns on, and a sink that holds VBUS up can stop a source from attaching at all. (Power Delivery’s own section on VBUS applied externally covers sources.) Unplugged and running on battery, the receptacle’s VBUS pin should read near zero. Several inputs feeding each other are covered in the multiple-sources article.
PPS and AVS: moving the charger’s heat into the adapter
Programmable Power Supply lets a sink request a voltage in 20 mV steps and an operating current in 50 mA steps. In PD R3.3 the ranges are 5 to 11, 5 to 16 and 5 to 21 V, typically at 3 A. The sink has to keep re-requesting while it uses PPS; the source treats silence as a fault and hard-resets, so a firmware crash mid-charge drops VBUS. The minimum changed between revisions: R3.3 marks 3.3 V as a deprecated minimum and requires 5 V, and older adapters advertise 3.3 V. PPS is optional for sources. PD 3.2 also added adjustable supplies (AVS) from 9 V, in 100 mV steps.
The point is heat. A linear charger dissipates (Vin − Vbat) × I. Charging a two-cell pack at 1 A from fixed 9 V with the pack at 6.0 V (3.0 V a cell, an example), it dissipates (9 − 6) × 1 = 3 W. Requesting a PPS voltage 0.3 V above the pack (an example headroom, measured at the charger’s input, since the cable can drop more than that) and raising it as the pack charges brings that to 0.3 W, and the conversion loss moves into the adapter. PPS sources also have a current-limit mode, which charging schemes that connect the adapter almost straight to the cells rely on.
The 5 V floor matters for one cell, which charges to about 4.2 V: tracking it directly needs an adapter still offering the deprecated 3.3 V. A two-cell pack, charged to 8.4 V, sits inside 5 to 11 V. One cell can still use PPS through a switched-capacitor stage that halves the voltage, with the adapter running at about twice the cell voltage. Either way the firmware joins the charge loop: it measures the cell, steps the request, and falls back safely when the adapter lacks PPS or hard-resets. Worst-case charger heat is in the multiple-sources article.
EPR: 28, 36 and 48 V
The extended power range raises the ceiling from 100 to 240 W with fixed 28, 36 and 48 V at up to 5 A, and adjustable supplies from 15 V up to those in 100 mV steps. Above 20 V needs a port above 100 W: 28 V over 100 W, 36 V over 140 W, 48 V over 180 W. Without an EPR-capable cable, an EPR source stays in the standard range.
That makes USB-C a realistic input for a 25 to 30 V pack, charged from 36 V, but the product still has to charge, more slowly, from a 20 V adapter or a 5 V port, so the charger has to boost as well as buck.
My preference is a product that charges, if slowly, from every port it can be plugged into.
Charge current plus system load against the advertisement
What has to fit under the port’s allowance is the input current, not the charge setting. On a switching charger that’s the cell’s charge power plus the system’s power, divided by the efficiency and the input voltage, (Vbat × Icharge + Vsys × Isys) / (η × Vin); on a linear one, the currents add. Then check it with the input limit at the top of its tolerance. The power path article works through the split.
On one sample board, charge current plus system load came to more than 500 mA, the most a configured USB 2.0 port, or a USB 2.0 Type-C port at Default USB Power, has to supply, and nothing read what the port advertised. On a strict port the voltage sags and the device resets or stops charging. The fix is an input limit that follows the source: 100 mA until something better is known, then what enumeration, Battery Charging detection, the CC level or the PD contract allows.
Voltage is the other half: the cable’s VBUS and ground conductors and both connectors drop some before the charger. From a 5 V supply at the bottom of its range, 4.75 V, to a charger whose input regulation can start at 4.63 V, there’s 120 mV for the round trip: 40 mΩ at 3 A, 80 mΩ at 1.5 A. The Type-C specification allows a cable 500 mV of drop on VBUS and 250 mV on ground, 750 mV in all, so a compliant 3 A cable from a 4.75 V source can leave about 4.0 V at the receptacle. A charger whose input regulation starts at 4.5 V or more will throttle 5 V, 3 A charging on a perfectly compliant cable: set its threshold lower if it allows, or negotiate a higher voltage. An input fuse or protection switch eats into the same budget. A higher PD voltage helps: at 9 V, 15 W is 1.67 A instead of 3 A.
Bench checks for a USB-C sink
- Attach to enumeration, processor in reset, on a computer port: steady current within 100 mA (150 mA on USB 3.x), and no more than 10 µF on VBUS at the connector.
- A marked cable both ways up; the input limit following each source and a mid-charge change.
- Host asleep: 2.5 mA or less.
- A 4.75 V source through the longest shipped cable: charge current against the setting.
- Hard reset with a dead cell: reboots, renegotiates, charges. With PPS, stop the firmware mid-charge and check what follows.
The EU common charger rule
Directive (EU) 2022/2380 amended the Radio Equipment Directive to require a common charger on handheld mobile phones, tablets, digital cameras, headphones, headsets, handheld videogame consoles, portable speakers, e-readers, keyboards, mice, portable navigation systems, earbuds and laptops, in so far as they can be recharged by wired charging. As a Radio Equipment Directive rule, it reaches those that are radio equipment. It applies from 28 December 2024, and for laptops from 28 April 2026.
The product needs a USB Type-C receptacle as described in EN IEC 62680-1-3, accessible and operational at all times, and must charge with cables complying with that standard. If it can be recharged by wired charging “at voltages higher than 5 Volts, currents higher than 3 Amperes or powers higher than 15 Watts”, it must incorporate USB Power Delivery as described in EN IEC 62680-1-2, and any additional charging protocol must allow the full functionality of USB Power Delivery, whatever charger is used. Any one of the three triggers it: a product charging at 9 V and 1 A needs PD at 9 W, and a proprietary fast-charge scheme can sit beside PD but not replace it. One that stays at 5 V and 3 A or less, everything Type-C advertisement covers, needs the receptacle but not PD. Where it’s sold with a charger, it must also be offered without one, with a pictogram on the packaging saying which, and the product’s information must state the charger power it needs. The list of product categories is closed: a product outside it isn’t covered, whatever it charges from. The wider EU picture is in Compliance by market, and the compliance planner lists the approvals for a product and its markets.
If you’re designing a product that charges from USB-C and want the sink side checked against what each port actually promises, get in touch.