Can you charge a lithium battery below freezing? Charge temperature limits
You can’t charge most lithium-ion cells below freezing (0 °C, 32 °F). Their datasheets set the lower charge limit at 0 °C, measured at the cell’s surface, because charging a graphite electrode in the cold can plate metallic lithium on it, which permanently costs capacity and can grow into an internal short. The usual charge window is 0 to 45 °C (32 to 113 °F) for energy cells and up to 60 °C for some power cells, and some cells ask for less current below 10 to 20 °C, such as 0.25C below 10 °C on one 18650 sheet. Discharge is allowed over a much wider range, typically −20 to 60 °C. Some LiFePO4 cells allow a small current below 0 °C and lithium titanate cells are rated to charge well below freezing, so the cell’s datasheet decides, not the chemistry’s name.
Many chargers follow the zones of the JEITA guideline: a standard range at full current and voltage, a cool band with less current, a warm band with a lower voltage, and no charging outside them. The guideline gives one set of numbers, for cobalt-type cells: 4.25 V, 0.7 ItA (a 0.7C rate), and a standard range of 10 to 45 °C. The familiar 0, 10, 45 and 60 °C edges with half current and 4.1 V are charger implementations, and many basic chargers have only a hot and cold cutoff or no cell temperature input at all. The terms used here are defined in How lithium-ion charging works.
What goes wrong in a cold cell
A lithium-ion cell charges by moving lithium into the graphite of its negative electrode, which takes it in at 65 to 200 mV above the potential of lithium metal. Push the electrode below lithium’s own potential and the lithium can deposit on the surface as metal instead. That’s plating. One review describes it as a balance between how fast the electrode can accept lithium and how fast the charging current delivers it, with temperature, state of charge and charge rate all moving the balance. Cold slows the electrode, so at the same current lithium arrives faster than it can go in; the JEITA guideline gives the same reason for its low range.
Some plated lithium strips back off on the next discharge. What doesn’t, called dead lithium, is capacity lost for good and a rise in internal resistance, and plated metal can grow into an internal short. One study, charging cells progressively colder and faster, saw charging shift from normal intercalation to plating and finally fail at −20 °C and 0.5C. A review of aging names plating as one cause of the knee, where slow capacity loss turns abruptly fast, and notes that plating can occur even at 1C near room temperature. There’s no universal temperature where it starts; the limit is what the cell maker tested that cell to.
State of charge shows up in some cell tables. One 4.4 V pouch cell, between 0 and 10 °C, allows 0.5C only to 4.1 V and then 0.2C to full: less current as the cell fills, where the electrode is closest to plating.
Discharging doesn’t plate, because lithium is leaving the graphite, which is why the discharge window reaches so much further down. A cold cell has higher resistance and less usable capacity, and some cells limit the discharge current too: one 4.35 V pouch cell allows 2.0C above 20 °C, 0.5C from 0 to 20 °C and 0.2C below 0 °C. One LiFePO4 prismatic cell lowers its end-of-discharge voltage from 2.5 V to 2.0 V at or below 0 °C. The charger’s thermistor input does nothing once the product is unplugged, so a discharge over-temperature limit, around 60 °C on one cell sheet, has to come from the protection circuit or the firmware. And storage is a third window: storing a cell below freezing is normally fine, while storing it full and hot ages it with no charger involved.
What heat does
At the hot end the concern is the positive electrode. The guideline’s reason for its high range is that instability of the positive electrode’s crystal structure is likely to lower safety, and the warm band answers it with a lower charge voltage. Heat also speeds aging, most of all in a cell that’s both full and hot.
The weather doesn’t have to be hot. A closed case in the sun, a car’s dashboard or a wireless charging pad can take a cell past its charge limit in a comfortable room. A linear charger dissipates the input-to-cell voltage difference times the current on the board beside the cell, and every charging cell heats itself through its internal resistance.
On one sample board, the charger sat on the side of the board facing the cell, running hot, and nothing measured the cell’s temperature at all, so nothing would notice if the cell went past its limit.
What cell datasheets allow
The windows differ more than the usual “0 to 45 °C” suggests. From the cell datasheets read for this series:
| Cell | Charge | Discharge | Reduced charging |
|---|---|---|---|
| 4.2 V cylindrical energy cell (18650) | 0 to 45 °C | −20 to 60 °C | 0.25C below 10 °C |
| 4.2 V cylindrical power cell (21700) | 0 to 60 °C ambient; cell surface up to 70 °C | −40 to 60 °C ambient | Current against surface temperature, as a graph |
| 4.2 V pouch cell | 0 to 45 °C | −10 to 60 °C | 0.3C at 0 to 15 °C, 0.5C at 15 to 25 °C, 1.0C at 25 to 45 °C |
| 4.35 V pouch cell | 0 to 45 °C | −20 to 60 °C | Standard rate only at 0 to 20 °C; up to 1.0C at 20 to 45 °C |
| 4.4 V pouch cell | 0 to 50 °C in its summary; its charge table runs to 60 °C | −20 to 60 °C | 0.5C to 4.1 V then 0.2C at 0 to 10 °C; 0.5C to 4.1 V only at 45 to 60 °C |
| LiFePO4 cylindrical power cell | 0 to 60 °C; under 250 mA below 0 °C “for some applications” | −30 to 60 °C | Not stated |
| LiFePO4 prismatic cell, 80 Ah | 0 to 55 °C; none below 0 °C | Not in the table read | 0.2C to 3.60 V at 0 to 10 °C; below 3.60 V only, under 0.2C at 45 to 50 °C and 0.1C at 50 to 55 °C |
Every sheet read puts the lower limit for normal charging at 0 °C; the upper runs from 45 to 60 °C, and the cool band starts at 10, 15 or 20 °C. The 4.4 V cell’s summary and charge table disagree about the top of the window, so read the whole sheet and take the tighter number. Its warm row cuts current as well as voltage, as many cells do. Three of the cells have more steps than a typical charger’s four zones can follow, so either the charger’s full-current setting drops to the lower step, or firmware follows the table.
LiFePO4 isn’t the cold-weather answer it’s sometimes taken for. The sheets read either forbid charging below 0 °C or, on one power cell, allow under 250 mA there, about 0.1C, and a pack maker’s manual says don’t charge at 0 °C or colder. One maker lowers the voltage as well as the current in the cool band, and the upper limit runs from 45 °C on several sheets to 55 or 60 °C on others.
Lithium titanate is different: its negative electrode isn’t graphite, and it works well above the potential where lithium plates. One 45 Ah cell’s sheet recommends no more than 1C below 0 °C and quotes at least 90 percent of initial capacity charged at −20 °C and 65 percent at −40 °C, at about a third of that current. Another maker’s sheet gives 2.9 V as the charge cutoff from −40 to 20 °C and 2.8 V above, though a paper’s table for a sister cell bands it the other way, so check the sheet for the exact cell.
The JEITA zones, and what chargers do with them
The guideline, written for 100 to 5,000 mAh cells in notebook computers, defines temperatures by role: T2 to T3 is the standard range, T1 to T2 and T3 to T4 the low and high ranges with reduced settings, and below T1 charging is to be avoided. Its numbers are the cobalt-cell proposal above. The 2021 revision, which adds tablets, still calls 10 to 45 °C typical and leaves the values to the cell maker. Every temperature in it is cell surface temperature.
Charger chips fill in the rest. One chip maker’s application note takes 0 °C for T1 and 45 °C for T3 “as an example”, halves the current from 0 to 10 °C and drops the charge voltage to 4.06 V from 45 to 60 °C. One charger family suspends charging below 0 °C, halves the current from 0 to 10 °C, drops to 4.05 V above 45 °C and suspends above 60 °C, with options for a 20 percent cool-band current and a 4.1 V warm-band voltage. Its datasheet says JEITA recommends under 4.1 V when warm; the guideline doesn’t.
The figure lays one of those schemes against the 18650 energy cell from the table. As configured, the charger would keep charging between 45 and 60 °C at a lower voltage, where the cell’s datasheet doesn’t allow charging at all. The charger’s zones have to come from the cell’s datasheet.
The cool band needs the same check. On that 18650 cell, a charger set to the cell’s 0.5C maximum halves to 0.25C, nominally what the sheet asks below 10 °C, but the charge current’s own tolerance, about ±10 percent on common chargers, can put it at 0.275C; the 20 percent option gives 0.1C, with margin. The 4.2 V pouch cell is worse: a charger set to 1C halves to 0.5C from 0 to 10 °C, where the cell allows 0.3C, then runs the full 1C from 10 to 15 °C, more than three times the cell’s limit there, and from 15 to 25 °C, where it allows 0.5C. The 10 °C edge matches the 18650 by luck: the pouch cells in the table reduce from 15 and 20 °C.
The same charger family disables termination in the cool and warm bands, so a charge there holds the cell at the charge voltage until the safety timer ends it: hours at full voltage in the cool band, or a full cell held warm. At half or a fifth of the current the constant-current phase takes two or five times as long, and a cold cell’s higher resistance moves it into constant voltage earlier, so size the safety timer for the coldest charge you allow, and check that the same long timer doesn’t leave a cell held at its charge voltage in the warm band for hours.
A full cell that warms up
A cell charged to 4.2 V at 40 °C, then warmed past 45 °C, is above the 4.05 or 4.1 V the charger now allows. The charger can’t remove charge, so the cell sits full and hot until a load draws it down. Check what your charger’s recharge threshold does when the charge voltage steps down under a full cell (one family has a separate one for its hot band), and whether the charger treats a cell above its new, lower voltage as a battery-overvoltage fault.
On a plugged-in product with a power path, nothing draws it down. If it lives somewhere warm, one option is to run the system from the cell for a while to bring it under the warm-band voltage, or charge to that voltage all the time. A pack monitor with firmware-set limits can lower the primary charge cutoff in each band. Secondary protection is different: it’s an independent, permanent fail-safe that stays a fixed hardware limit above the normal charge voltage, and setting it from firmware would make it neither.
Measuring the cell, not the board
Every limit above is a cell surface temperature, and one cell maker says protection should be set based on the location of the cell surface temperature. What the charger reads is a thermistor somewhere, and where it is decides what it reports. The JEITA guideline says the same: with a single thermistor, choose its position from the temperature distribution in the battery as installed, and design for a spread in cell surface temperature of no more than 5 °C.
A thermistor on the board next to the charger reads the board, heated by the charger and everything else on it. One on a flex tail taped to the cell reads the cell, but a thick trace or large pad conducts heat and pulls it toward the board. The better place is held against the cell’s surface, away from heat sources, with thin traces leading away.
Many packs bring their own thermistor out on a third terminal, with a value and beta the pack maker chose, so the charger’s network has to be designed for that part, not the one on the charger’s datasheet. That thermistor is usually referenced to the cell’s negative, which moves when a low-side protection switch opens.
Thermal lag is the other half. The sensor and the cell have thermal mass and the path between them has thermal resistance, so the sensor follows the cell with a delay. Two cases make it matter:
- Cold soak. A product brought in from a freezing car warms from the outside in, so the thermistor reads a permitted temperature while the core is still cold. A minimum warm-up time after a cold reading covers it if the product was awake to see the cold; one that was off and is plugged in after coming indoors has no record, so a delay after plug-in, or a reduced current until the reading settles, is the safer rule.
- Self-heating during fast charge. The core runs warmer than the surface, and the surface warmer than a remote sensor, which under-reads exactly when the cell heats fastest.
The thermistor network
Most charger chips read the thermistor as a divider. A bias voltage drives a resistor network with an NTC thermistor in it (its resistance falls as it warms), and comparators trip at fixed fractions of the bias, one per zone edge. On one charger family, with the thermistor type its datasheet specifies:
| Edge | Minimum | Typical | Maximum |
|---|---|---|---|
| 0 °C (suspended below) | 72.4 % | 73.3 % | 74.2 % |
| 10 °C | 67.2 % | 68 % | 69 % |
| 45 °C | 43.8 % | 44.7 % | 45.8 % |
| 60 °C (suspended above) | 33.7 % | 34.2 % | 35.1 % |
Change the thermistor or the network and every edge moves, and two resistors can only place two edges; the others land where the thermistor’s curve puts them. Zones in registers, or a firmware charger reading the thermistor on an ADC, can set each edge independently.
Tolerance, in degrees
The comparator bands turn into degrees through the thermistor’s curve. With the specified 10 kΩ thermistor in that network, the fraction changes by only about 0.45 points per degree around 0 °C, because the resistor in parallel with the thermistor flattens the curve at the cold end, against about 0.7 points per degree around 45 °C. So the 0 °C comparator’s band of ±0.9 points puts that edge anywhere across about 4 °C, roughly ±2 °C around its nominal, and the 45 °C edge across about 3 °C, roughly ±1.5 °C. These are my estimates from a standard thermistor curve, not figures the chip maker gives.
That’s the comparator alone. The other errors add to it:
- The top resistor: off by 1 percent, it moves the fraction by f(1 − f) × 1 percent, about 0.2 points at 0 °C, which the flattened slope turns into about 0.5 °C.
- The parallel resistor: its own tolerance adds about 0.2 °C per percent at 0 °C, and by flattening the curve it’s also why every other error costs more degrees at the cold end.
- The thermistor itself: a 1 percent resistance error is about 0.22 °C at 0 °C (δ × T² / B), whatever the network, and its beta tolerance widens the error away from 25 °C, where its resistance is specified.
- The bias: its error cancels only if the network is fed from the reference the comparators use. From another rail, each percent of that rail’s error moves the fraction by about 0.73 points at 0 °C, about 1.6 °C, which can be the largest term.
Add them up and the charger’s 0 °C edge is a band a few degrees wide, part of it below 0 °C. If the cell mustn’t charge below 0 °C, the cold edge has to sit above 0 °C by the whole stack, plus whatever the sensor’s placement adds, and the hot edge below the cell’s limit the same way.
Open, shorted, and tied off
A thermistor can come unplugged or short, and each failure should read as a reason to stop. Read the charger’s own handling of out-of-range pin voltages first: some chargers treat a pin near the bias as “thermistor or battery absent” and change mode rather than stopping, and some treat a pin held low as charge-disable. On one charger’s recommended network, with a resistor from the bias to the pin and another in parallel with the thermistor, an open thermistor leaves the pin at about 85 percent of the bias, well above a cold threshold like the 74.2 percent maximum in the table, so it reads as too cold and charging stops. A shorted one pulls the pin to zero and reads as too hot. Choose the network differently, with a parallel resistor small against the top resistor, and an open thermistor can leave the pin inside the normal range, reading room temperature for ever. Check both failure readings against the thresholds at their worst tolerances.
A fixed resistor on the thermistor pin is a choice to have no temperature limit in the charger, safe only if something else enforces the window.
On one sample board, the thermistor input was tied to a fixed resistor, so the charger always saw a normal temperature, and there was no charge timer either. Nothing would stop a charge in heat or cold, and a cell charged outside its window ages fast and can swell.
A resistor on the thermistor pin that ends up unfitted fails the other way: the pin floats, and depending on the charger it may never charge at all.
Edges, hysteresis and what the user sees
An edge without hysteresis chatters, and self-heating makes it a real loop: a cell charging just under the warm edge heats itself across it, the charger backs off, the cell cools, and full charging resumes. Hysteresis on the comparators, or a minimum dwell time in firmware, stops it; check how much the charger’s datasheet gives.
To the user, a temperature pause looks like a fault: plugged in inside a cold car, the product doesn’t charge, and a light that shows only charging or not can’t say why. If the product can see the zone, give “too cold to charge” its own indication.
The charger’s own temperature is a different limit
Charger chips also protect themselves, holding the die at around 90 to 125 °C by cutting the charge current, and one family suspends charging at a 150 °C die. That reacts to the chip’s own dissipation, not the cell: a charger in thermal regulation can be charging a cell at 5 °C. It still affects the charge, because the chargers read disable termination while the thermal loop is cutting current, so a hot charger stretches a charge past its expected end.
A linear charger in a small package can spend whole charges in thermal regulation; the article on charging sources works its worst case and has a sample-board example.
Charging in the cold with a heater
A product that must charge below 0 °C, with a cell that mustn’t, needs a heater against the cell or pack, run until the cell is warm enough. The questions are where its power comes from and what happens when it fails.
From the charge input, the heater shares the input current with the charge, which on a weak source like a USB port leaves little for either; size the input for both, or heat first and charge after. From the pack, it runs on a discharge, which is allowed in the cold, but a flat pack can’t warm itself, and it’s the one that most needs charging, so the input path is needed either way. A pack-powered heater sits behind the pack’s protection and fuse like any other load.
Control follows the coldest part of the cell. A heater warms the cell’s surface first, and a thermistor near the heater reads warm long before the cell’s far side or core does, cold soak in reverse. Put the sensor that permits charging away from the heater, hold off charging for a time after it reads warm, and use hysteresis so the heater doesn’t cycle at the edge. The same placement means the cell face next to the heater runs hottest, so it needs its own over-temperature limit while the far side warms up. A heater stuck on warms a pack with no upper bound, so give it a thermal cutoff or a hardware comparator that opens it whatever the firmware is doing; the JEITA guideline asks for a current-blocking element such as a thermal fuse when a battery’s monitored temperature exceeds its upper limit.
Large packs: more than one sensor
Cells in a multi-cell pack don’t share one temperature: the middle runs warmer than the edges, and cells near a heater or charger warmer than the rest. Use several sensors and let both extremes gate the charge: the coldest decides whether charging is allowed at all and sets the cool-band current, and the hottest sets the warm-band voltage and current and the hot cutoff.
With several packs charging at once, each has its own temperature window, and one pack too cold to charge shouldn’t hold up the others.
Firmware can reject an open or shorted reading and flag a sensor that disagrees with its neighbours, but it shouldn’t be the only thing that stops a hot charge: a hardware cutoff on the sensors most likely to see the hottest cell survives a firmware fault.
Testing it
Resistors in place of the thermistor test the thresholds, the zone logic and the status output. Placement, lag and self-heating need a real cell in a temperature chamber.
- Resistors at each edge’s value from the thermistor’s table, at the network’s tolerance limits; then the thermistor open and shorted.
- A slow sweep across each edge, in both directions, watching for chatter.
- In a chamber, in the enclosure, thermocouples on the cell beside the thermistor, on the slowest face to warm and on the face nearest the board’s heat, logged against the charger’s state: cold-soak below 0 °C, plug in, and compare when charging starts with when the whole cell is warm.
- Full-current charging at the warmest rated ambient, with the other heat sources running, checking the cell’s surface stays inside its window.
- If there’s a heater, force it on and confirm the independent cutoff opens it.
In production, one resistor point at room temperature, or the thermistor reading against the fixture’s own temperature, confirms the network was built and fitted; Designing for production test covers where that check goes.
If your product has to charge outdoors, in a vehicle or next to its own heat, and you’d like the window, the thermistor network and its tolerances checked against your cell’s datasheet, get in touch.